S'abonner

Validation of Peripherally Inserted Central Catheter-Derived Fick Cardiac Outputs in Patients with Heart Failure - 08/12/17

Doi : 10.1016/j.amjcard.2017.09.020 
Kristen M. Tecson, PhD a, b, Anupama Vasudevan, PhD a, b, Amarinder Bindra, MD c, Susan M. Joseph, MD c, Joost Felius, PhD d, Shelley A. Hall, MD c, Parag Kale, MD b, c, *
a Baylor Heart and Vascular Institute, Baylor Scott & White Research Institute, Dallas, Texas 
b Department of Internal Medicine, Texas A&M University College of Medicine Health Science Center, Dallas, Texas 
c Center for Advanced Heart and Lung Disease, Baylor University Medical Center, Dallas, Texas 
d Annette C. and Harold C. Simmons Transplant Institute, Baylor Scott & White Research Institute, Dallas, Texas 

*Corresponding author: Tel: 214.820.6856; fax: 214.820.1474.

Abstract

The pulmonary artery catheter (PAC) remains the gold standard to calculate Fick cardiac outputs (FCOs) in patients with heart failure admitted to the intensive care unit (ICU). The peripherally inserted central catheter (PICC) provides long-term intravenous access and is used outside the ICU; however, there is scant literature validating venous oxygen saturations (VOSs) from PICC lines. Heart failure patients in the ICU with an existing PAC requiring a PICC line to transition were enrolled. Three blood samples were taken per person (1 at PICC, 1 at central venous pressure [CVP], and 1 at distal PAC). We performed repeated measures analysis of variance, as well as reliability analysis on 31 subjects (77% male, 71% Caucasian, mean ± standard deviation age 60 ± 8 years, 80% on inotropes). The average VOSs were 62 ± 11%, 62 ± 12%, and 61 ± 9% for the PICC line, CVP, and distal port, respectively (p = 0.66); there was excellent reliability (0.79). The median FCOs were 5 [4, 6], 5 [4, 6], and 5 [4, 6] L/min at the PICC, CVP, and distal port, respectively (p = 0.91); there was fair-to-good reliability (0.67). In conclusion, VOS and FCO did not differ by location, on average. Reliable data may be obtained through the PICC line, after evaluation from the PAC. The PICC may provide longer-term hemodynamic assessment while improving patient comfort.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 54 for disclosure information.


© 2017  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 121 - N° 1

P. 50-54 - janvier 2018 Retour au numéro
Article précédent Article précédent
  • Impact of Cardiorespiratory Fitness on Frequency of Atrial Fibrillation, Stroke, and All-Cause Mortality
  • Nasir Hussain, Bernard J. Gersh, Karina Gonzalez Carta, Nóra Sydó, Francisco Lopez-Jimenez, Stephen L. Kopecky, Randal J. Thomas, Samuel J. Asirvatham, Thomas G. Allison
| Article suivant Article suivant
  • Coronary Venous Dissection from Left Ventricular Lead Placement During Cardiac Resynchronization Therapy With Defibrillator Implantation and Associated in-Hospital Adverse Events (from the NCDR ICD Registry)
  • Jonathan C. Hsu, Paul D. Varosy, Haikun Bao, Thomas A. Dewland, Jeptha P. Curtis, Gregory M. Marcus

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.