S'abonner

Predicting Extubation Outcomes—A Model Incorporating Heart Rate Characteristics Index - 26/03/18

Doi : 10.1016/j.jpeds.2017.11.037 
Nitin Goel, MBBS, MD, FRCPCH 1, * , Mallinath Chakraborty, MBBS, DCh, FRCPCH, PhD 2, 3, William John Watkins, PhD 4, Sujoy Banerjee, MBBS, DCh, MD, MA, MRCP, MRCPCH 1
1 Neonatal Intensive Care Unit, Singleton Hospital, Swansea, United Kingdom 
2 Regional Neonatal Intensive Care Unit, University Hospital of Wales, Cardiff, United Kingdom 
3 Department of Postgraduate Medicine and Dentistry, Cardiff University, Cardiff, United Kingdom 
4 Department of Infection and Immunity, Cardiff University, Cardiff, United Kingdom 

*Reprint requests: Nitin Goel, MBBS, MD, FRCPCH, Neonatal Intensive Care Unit, Singleton Hospital, Sketty Lane, Swansea SA2 8QA, UK.Neonatal Intensive Care UnitSingleton HospitalSketty LaneSwanseaSA2 8QAUK

Abstract

Objective

To test the hypothesis that in neonates on mechanical ventilation, heart rate characteristics index (HRCi) can be combined with a clinical model for predicting extubation outcomes in neonates.

Study design

HRCi and clinical data for all intended intubation-extubation events (episodes) were retrospectively analyzed between June 2014 and January 2015. Each episode started 6 hours pre-extubation or at the time of primary intubation if ventilation duration was shorter than 6 hours (baseline). The episodes ended at 72 hours postextubation for successful extubations or at reintubation for failed extubations. Mean of 6 hourly epoch HRCi-scores (baseline) or fold-changes (postextubation) were analyzed. Results are expressed as medians (IQR) for continuous data and proportions for categorical data. Multivariable logistic regression mixed model was used for statistical analysis.

Results

Sixty-six infants contributed to 96 episodes (18 failed extubations, 78 successful extubations) in the study. Failed extubations had significantly longer duration of ventilation (65.3 hours, 19.94-158.2 vs 38.4, 16.5-71.3) and more culture positive sepsis (33.3% vs 3.8%) than successful extubations. Baseline HRCi scores (1.68, 1.29-2.45 vs 0.95, 0.54-1.86) and postextubation epoch-1 fold changes (1.25, 0.94-1.55 vs 0.94, 0.82-1.11) were higher in failed extubations compared with successful extubations. Multivariable linear mixed-effects regression was used to create prediction models for success of extubation, using relevant variables.

Conclusions

The baseline and postextubation HRCi were significantly higher in neonates with extubation failure compared with those who succeeded. Models using HRCi and clinical variables to predict extubation success may add to the confidence of clinicians considering extubation.

Le texte complet de cet article est disponible en PDF.

Keywords : mechanical ventilation, predicting successful extubation, respiratory failure, neonate, heart rate characteristics

Abbreviations : GA, HRCi, PEE


Plan


 The authors declare no conflicts of interest.


© 2017  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 195

P. 53 - avril 2018 Retour au numéro
Article précédent Article précédent
  • Utility of Early-Onset Sepsis Risk Calculator for Neonates Born to Mothers with Chorioamnionitis
  • David Carola, Mansi Vasconcellos, Amy Sloane, Dorothy McElwee, Caroline Edwards, Jay Greenspan, Zubair H. Aghai
| Article suivant Article suivant
  • Outcome of Preterm Infants with Transient Cystic Periventricular Leukomalacia on Serial Cranial Imaging Up to Term Equivalent Age
  • Subrata Sarkar, Seetha Shankaran, John Barks, Barbara T. Do, Abbot R. Laptook, Abhik Das, Namasivayam Ambalavanan, Krisa P. Van Meurs, Edward F. Bell, Pablo J. Sanchez, Susan R. Hintz, Myra H. Wyckoff, Barbara J. Stoll, Waldemar A. Carlo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.