S'abonner

ERCP performed through previously placed duodenal stents: a multicenter retrospective study of outcomes and adverse events - 14/05/18

Doi : 10.1016/j.gie.2018.01.040 
Judith Staub, MD 1, Ali Siddiqui, MD 2, Linda Jo Taylor, BS 1, David Loren, MD 2, Tom Kowalski, MD 2, Douglas G. Adler, MD 1,
1 Gastroenterology and Hepatology, University of Utah School of Medicine, Salt Lake City, Utah, USA 
2 Gastroenterology and Hepatology, Jefferson University School of Medicine, Philadelphia, Pennsylvania, USA 

Reprint requests: Douglas G. Adler, MD, FACG, AGAF, FASGE, Professor of Medicine, Director of Therapeutic Endoscopy, Director, GI Fellowship Program, Gastroenterology and Hepatology, University of Utah School of Medicine, Huntsman Cancer Center, 30N 1900E 4R118, Salt Lake City, UT 84132.Professor of MedicineDirector of Therapeutic EndoscopyDirector, GI Fellowship ProgramGastroenterology and HepatologyUniversity of Utah School of MedicineHuntsman Cancer Center30N 1900E 4R118Salt Lake CityUT84132

Abstract

Background and Aims

ERCP performed through previously placed enteral stents is an uncommon procedure without a significant amount of supporting literature and with a wide reported range of technical success. The purpose of this study was to evaluate and better define the technical feasibility and safety of performing ERCP through enteral stents in patients with combined malignant biliary and gastric outlet obstruction.

Methods

We conducted a multicenter, retrospective study on 71 patients with combined gastric outlet and biliary obstruction who underwent ERCP through a previously placed enteral stent at 2 tertiary care centers. Outcomes included but were not limited to technical success, clinical success, need for repeat ERCP, adverse events, and survival time.

Results

Overall technical success was achieved in 60 of 71 patients (85%), with technical success of 40 of 46 (87%) in type I obstructions (gastric outlet obstruction above the ampulla), 16 of 21 (76%) in type II obstructions (gastric outlet obstruction at the level of the ampulla), and 4 of 4 (100%) in type III obstructions (gastric outlet obstruction distal to the ampulla). In general, patients who achieved technical success also achieved clinical success. Adverse events occurred in 3 patients (3/71): 2 patients with acute cholangitis and 1 patient with perforation. Average survival time after the procedure was 4.6 months overall.

Conclusions

ERCP performed through enteral stents is safe, with a high technical and clinical success rate, but may be more technically challenging in the setting of type II obstructions. This procedure could be considered first line in the unique setting that a patient requires ERCP through a previously placed enteral stent for malignant gastric outlet and biliary obstruction.

Le texte complet de cet article est disponible en PDF.

Plan


 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: A. Siddiqui, D. Loren, T. Kowalski: Consultant for Boston Scientific. A. Siddiqui: Consultant, grant recipient from Medtronic. D. G. Adler: Consultant for Boston Scientific and Merit. All other authors disclosed no financial relationships relevant to this publication.


© 2018  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 87 - N° 6

P. 1499-1504 - juin 2018 Retour au numéro
Article précédent Article précédent
  • Impact of capsule endoscopy on prevention of postoperative recurrence of Crohn’s disease
  • Ze-min Han, Wei-guang Qiao, Xiu-yun Ai, Ai-min Li, Zhen-yu Chen, Xi-cheng Feng, Jie Zhang, Tian-mo Wan, Zhi-min Xu, Yang Bai, Ming-song Li, Si-de Liu, Fa-chao Zhi
| Article suivant Article suivant
  • Prediction of clinical outcomes in Crohn’s disease by using confocal laser endomicroscopy: results from a prospective multicenter study
  • Gian Eugenio Tontini, Jonas Mudter, Michael Vieth, Claudia Günther, Valentina Milani, Raja Atreya, Timo Rath, Andreas Nägel, Giorgia Hatem, Giacomo Carlo Sturniolo, Maurizio Vecchi, Markus F. Neurath, Peter R. Galle, Andrea Buda, Helmut Neumann

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.