S'abonner

Meta-Analysis Comparing Outcomes After Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents in Patients with Acute Coronary Syndromes - 07/06/18

Doi : 10.1016/j.amjcard.2018.03.003 
Roberta De Rosa, MD, PhD a, Angelo Silverio, MD a, Attilio Varricchio, MD, PhD b, Giuseppe De Luca, MD, PhD c, Marco Di Maio, MD d, Ilaria Radano, MD a, Marta Belmonte, MD a, Maria Carmen De Angelis, MD, PhD b, Elisabetta Moscarella, MD b, Rodolfo Citro, MD a, Federico Piscione, MD, PhD a, * , Gennaro Galasso, MD, PhD a
a Department of Cardiology, San Giovanni di Dio e Ruggi d'Aragona University Hospital, Salerno, Italy 
b Division of Cardiology, S. Maria della Pietà Hospital, Nola, Italy 
c Division of Cardiology, AOU “Maggiore della Carità”, Eastern Piedmont University, Novara, Italy 
d Department of Cardiovascular Science, Second University of Naples, AO dei Colli, Monaldi, Napoli, Italy 

*Corresponding author: Tel: 0039 89 673182; fax: 003989673314.

Abstract

Acute coronary syndromes (ACS) may represent an intriguing clinical scenario for implantation of bioresorbable vascular scaffold (BRS). Nevertheless, the knowledge about the performance of these devices in patients with ACS is limited. Therefore, we performed a meta-analysis of clinical studies aiming to assess the safety and efficacy of everolimus-eluting-BRS versus everolimus-eluting-metallic stents (EES) in ACS patients undergoing percutaneous coronary intervention. Six studies enrolling 2,318 patients were included and analyzed for the risk of primary safety outcome (stent or scaffold thrombosis [ST/ScT]), primary efficacy outcome (target lesion revascularisation [TLR]), and secondary outcomes (myocardial infarction, cardiac death, all-cause death). Median follow-up was 9.5 (6 to 19.5) months. Patients treated with BRS had a significantly higher risk of definite ST/ScT compared with those receiving EES (2.3% vs 1.08%, odds ratio [OR] 2.22, 95% confidence interval [CI] 1.10 to 4.45, p = 0.03, I2 = 0%). Similarly, the risk of TLR was significantly higher in the BRS compared with EES group (3.5% vs 2.5%, OR 1.79, 95% CI 1.02 to 3.16, p = 0.04, I2 = 0%). When TLRs due to thrombosis were excluded, the difference in risk estimates between the 2 groups was no longer significant (OR 1.19, 95% CI 0.48 to 2.98, p = 0.71, I2 = 25%). Risk for secondary endpoints did not differ between the 2 groups. Results were confirmed when clinical and procedural variables were tested as potential effect modifiers in the meta-regression analysis for both primary endpoints. In conclusion, compared with those receiving EES, patients with ACS treated with BRS had increased risk of definite device thrombosis and TLR at mid-term follow-up.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 67 for disclosure information.


© 2018  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 122 - N° 1

P. 61-68 - juillet 2018 Retour au numéro
Article précédent Article précédent
  • Three-Year Impact of Immediate Invasive Strategy in Patients With Non–ST-Segment Elevation Myocardial Infarction (from the RIDDLE-NSTEMI Study)
  • Dejan Milasinovic, Aleksandra Milosevic, Zorana Vasiljevic-Pokrajcic, Jelena Marinkovic, Vladan Vukcevic, Branislav Stefanovic, Milika Asanin, Sanja Stankovic, Branislava Ivanovic, Goran Stankovic
| Article suivant Article suivant
  • Effectiveness and Safety of Direct Oral Anticoagulants and Warfarin, Stratified by Stroke Risk in Patients With Atrial Fibrillation
  • Inmaculada Hernandez, Yuting Zhang, Samir Saba

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.