Validation of Transient Elastography Cut Points to Assess Advanced Liver Fibrosis in Children and Young Adults: The Boston Children's Hospital Experience - 22/06/18

Doi : 10.1016/j.jpeds.2018.02.062 
Christine K. Lee, MD 1, * , Paul D. Mitchell, MS 2, Roshan Raza, MBBS 1, Sarah Harney, BA 1, Shanna M. Wiggins, BS 1, Maureen M. Jonas, MD 1
1 Division of Gastroenterology, Hepatology and Nutrition, Boston Children's Hospital, Boston, MA 
2 Institutional Centers for Clinical and Translational Research, Boston Children's Hospital, Boston, MA 

*Reprint requests: Christine K. Lee, MD, Division of Gastroenterology and Nutrition, Boston Children's Hospital/ Harvard Medical School, 300 Longwood Ave, Hunnewell Ground, Boston, MA 02115.Division of Gastroenterology and NutritionBoston Children's Hospital/ Harvard Medical School300 Longwood AveHunnewell GroundBostonMA02115

Abstract

Objective

To derive an optimal liver stiffness measurement cut point to discriminate METAVIR fibrosis stage F4 and to validate both METAVIR fibrosis stage F3-F4 and F4 cut points in a separate cohort.

Study Design

Patients at Boston Children's Hospital with liver stiffness measurement from 2006 to 2016 and liver biopsy ≤12 months before screening were eligible. Patients enrolled 2006-2011 were used to calibrate liver stiffness measurement cut points and those enrolled 2011-2016 for validation. Diagnostic performance was assessed by receiver operating curve analysis.

Results

In total, 267 subjects were enrolled (97 calibration, 170 validation). The cohorts were similar with 54% male, aged 0-29 years (median 13 years), and liver diseases including 21% autoimmune, 19% viral, 11% nonalcoholic fatty liver, 9% cholestatic, and 9% primary sclerosing cholangitis. Cut points to discriminate F3-F4 and F4 were >8.6 kPa and >11.5 kPa with 81% and 84% accuracy, respectively. Applied to the validation cohort, accuracy was 67% and 75%, respectively. In 44 fasted subjects, the accuracy was 73% and 80%, respectively.

Conclusion

This study validates previously determined liver stiffness measurement cut points of 8.6 kPa and 11.5 kPa to predict METAVIR F3-F4 and F4 fibrosis in children and young adults in separate cohorts. With increasing data on the utility and validity of liver stiffness measurement in children, transient elastography may help identify patients with greater risk of advanced fibrosis and those who need liver biopsy assessment and/or surveillance for the complications of cirrhosis in a variety of liver disorders.

Le texte complet de cet article est disponible en PDF.

Abbreviations : AUROC, S, TP


Plan


 Echosens provided the transient elastography machine and did not have a role in (1) study design; (2) collection, analysis, or interpretation of data; (3) writing of the manuscript; or (4) the decision to submit the paper for publication. The authors declare no conflicts of interest.


© 2018  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 198

P. 84 - juillet 2018 Retour au numéro
Article précédent Article précédent
  • Clinically Actionable Hypercholesterolemia and Hypertriglyceridemia in Children with Nonalcoholic Fatty Liver Disease
  • Kathryn E. Harlow, Jonathan A. Africa, Alan Wells, Patricia H. Belt, Cynthia A. Behling, Ajay K. Jain, Jean P. Molleston, Kimberly P. Newton, Philip Rosenthal, Miriam B. Vos, Stavra A. Xanthakos, Joel E. Lavine, Jeffrey B. Schwimmer
| Article suivant Article suivant
  • A Mediation Analysis on the Relationship of Physical Fitness Components, Obesity, and Academic Performance in Children
  • Adrià Muntaner-Mas, Pere Palou, Josep Vidal-Conti, Irene Esteban-Cornejo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.