Résumé

Background

B-type natriuretic peptide (BNP) has been found to be inversely related to peak oxygen consumption (peak VO2) in various patient populations. However, in these studies, circulating plasma BNP, i.e. the net effect of release and elimination, rather than cardiac BNP release has been measured. We assessed the relationship between the transcardiac BNP gradient [ΔBNPCS-A, i.e. the difference between BNP in coronary sinus (BNPCS) and arterial (BNPA) plasma] and peak VO2 in healthy subjects with a view to better understanding the regulation of cardiac BNP release in humans.

Methods

We studied 10 asymptomatic subjects (age 64±11 years, two females) with preserved left ventricular function (left ventricular ejection fraction 62±5%, averaged early diastolic mitral annular velocity 9±3cm/s) and low BNP (BNP in venous plasma [BNPV] <100ng/l). Subjects underwent measurement of BNPA and BNPCS for the calculation of ΔBNPCS-A, maximal cardiopulmonary exercise testing, echocardiography and resting and submaximal exercise right heart catheterisation.

Results

The median (range) BNPV, BNPA, BNPCS, and ΔBNPCS-A were 62 (14, 82), 60 (13, 79), 110 (25, 157), and 44 (1, 103) ng/l. The median peak VO2 during cardiopulmonary exercise testing was 21.5 (18, 54) ml/min/kg. There was an inverse correlation between higher ΔBNPCS-A and lower peak VO2 (r=−0.84; p=0.002) and oxygen pulse (r=−0.64, p=0.049). There was a trend towards an inverse correlation between ΔBNPCS-A and the exercise arteriovenous oxygen content difference (r=−0.58; p=0.08).

Conclusions

In healthy humans, there is an inverse association between myocardial BNP release and peak VO2, which may be due to cardiac and non-cardiac mechanisms.

Le texte complet de cet article est disponible en PDF.

Keywords : B-type natriuretic peptide, Myocardial, Transcardiac, Peak oxygen consumption


Plan


© 2017  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 27 - N° 8

P. 995-1003 - août 2018 Retour au numéro
Article précédent Article précédent
  • Elective Cardioversion in the Era of Novel Oral Anticoagulants – Does a Nurse Administered Verbal Questionnaire for Compliance Negate the Need for Routine Transoesophageal Echocardiography?
  • Matthew K. Rowe, Naomi Lollback, Leanne Slater, John Hill, Paul A. Gould, Gerald C. Kaye
| Article suivant Article suivant
  • A Comparative Study of Histopathological Changes in the Ascending Aorta and the Risk Factors Related to Histopathological Conditions and Aortic Dilatation in Patients With Tetralogy of Fallot and a Functionally Univentricular Heart
  • Ujjwal K. Chowdhury, Sheil Avneesh, Ruma Ray, Srikrishna M. Reddy, Mani Kalaivani, Suruchi Hasija, Lakshmi Kumari

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.