S'abonner

New technologies improve adenoma detection rate, adenoma miss rate, and polyp detection rate: a systematic review and meta-analysis - 16/07/18

Doi : 10.1016/j.gie.2018.03.022 
Daniel Castaneda, MD 1, ⁎∗, Violeta B. Popov, MD, PhD 2, ∗, Elijah Verheyen, MD 1, Praneet Wander, MD 3, Seth A. Gross, MD 4
1 Department of Medicine, Mount Sinai St. Luke’s–West Hospitals, Icahn School of Medicine, New York, New York, USA 
2 Division of Gastroenterology, New York VA Harbor Healthcare, NYU School of Medicine, New York, New York, USA 
3 Department of Gastroenterology, Northshore Long Island Jewish Hospital, New York, New York, USA 
4 Clinical Care and Quality, Division of Gastroenterology, NYU Langone Health, NYU School of Medicine, New York, New York, USA 

∗Reprint requests: Daniel Castaneda, MD, Department of Medicine, Mount Sinai St. Luke’s–West Hospitals, Icahn School of Medicine, 1000 Amsterdam Avenue, Suite 3A-09, New York, NY 10019.Department of MedicineMount Sinai St. Luke’s–West HospitalsIcahn School of Medicine1000 Amsterdam Avenue, Suite 3A-09New YorkNY10019

Abstract

Background and Aims

The need to increase the adenoma detection rate (ADR) for colorectal cancer screening has ushered in devices that mechanically or optically improve conventional colonoscopy. Recently, new technology devices (NTDs) have become available. We aimed to compare the ADR, polyp detection rate (PDR), and adenoma miss rate (AMR) between NTDs and conventional colonoscopy and between mechanical and optical NTDs.

Methods

MEDLINE and Embase databases were searched from inception through September 2017 for articles or abstracts reporting ADR, PDR, and AMR with NTDs. Randomized controlled trials and case-control studies with >10 subjects were included. Primary outcomes included ADR, PDR, and AMR odds ratio (OR) between conventional colonoscopy and NTDs. Secondary outcomes included cecal intubation rates, adverse events, cecal intubation time, and total colonoscopy time.

Results

From 141 citations, 45 studies with 20,887 subjects were eligible for ≥1 analyses. Overall, the ORs for ADR (1.35; 95% confidence interval [CI] 1.24-1.47; P < .01) and PDR (1.51; 95% CI, 1.37-1.67; P < .01) were higher with NTDs. Higher ADR (OR, 1.52 vs 1.25; P = .035) and PDR (OR, 1.63 vs 1.10; P ≤ .01) were observed with mechanical NTDs. The overall AMR with NTDs was lower compared with conventional colonoscopy (OR, .19; 95% CI, .14-.26; P < .01). Mechanical NTDs had lower AMRs compared with optical NTDs (OR, .10 vs .33; P < .01). No differences in cecal intubation rates, cecal intubation time, or total colonoscopy time were found.

Conclusions

Newer endoscopic technologies are an effective option to improve ADR and PDR and decrease AMR, particularly with mechanical NTDs. No differences in operability and safety were found.

Le texte complet de cet article est disponible en PDF.

Abbreviations : ADR, AMR, CI, FUSE, NTD, OR, PDR


Plan


 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: V. B. Popov: Research support recipient from Spatz and Apollo Endosurgery. S. A. Gross: Consultant for Olympus and Medivators. All other authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Castaneda at [email protected].


© 2018  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 88 - N° 2

P. 209 - août 2018 Retour au numéro
Article précédent Article précédent
  • How I perform sphincterotomy
  • Lars Aabakken, Gregory Haber
| Article suivant Article suivant
  • Optimizing duodenoscope reprocessing: rigorous assessment of a culture and quarantine protocol
  • Jennifer T. Higa, Jaehoon Choe, Deborah Tombs, Michael Gluck, Andrew S. Ross

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.