S'abonner

Cost-effectiveness analysis comparing lumen-apposing metal stents with plastic stents in the management of pancreatic walled-off necrosis - 16/07/18

Doi : 10.1016/j.gie.2018.03.021 
Yen-I Chen, MD 1, Alan N. Barkun, MD, CM, MSc 1, Viviane Adam, MSc 1, Ge Bai, PhD 3, Vikesh K. Singh, MD, MSc 2, Majidah Bukhari, MD 2, 6, Olaya Brewer Gutierrez, MD 2, B. Joseph Elmunzer, MD, MSc 4, Robert Moran, MD 2, Lea Fayad, MD 2, Mohamad El Zein, MD 2, Vivek Kumbhari, MD 2, Alessandro Repici, MD 5, Mouen A. Khashab, MD 2,
1 Division of Gastroenterology and Hepatology, The McGill University Health Center, Montreal, Quebec, Canada 
2 Division of Gastroenterology and Hepatology, Johns Hopkins Medical Institutions, Baltimore, Maryland, USA 
3 Johns Hopkins Carey Business School, Baltimore, Maryland, USA 
4 Division of Gastroenterology and Hepatology, Medical University of South Carolina, Charleston, South Carolina, USA 
5 Gastroenterology, Humanitas Clinical and Research Hospital, IRCCS, Rozanno, Italy 
6 King Faisal Specialist Hospital and Research Center, Jeddah, Saudi Arabia 

Reprint requests: Mouen A. Khashab, MD, Division of Gastroenterology and Hepatology, Johns Hopkins Hospital, 1800 Orleans Street, Suite 7125B, Baltimore, MD 21287.Division of Gastroenterology and HepatologyJohns Hopkins Hospital1800 Orleans Street, Suite 7125BBaltimoreMD21287

Abstract

Background and Aims

EUS-guided transmural drainage is effective in the management of pancreatic walled-off necrosis (WON). A lumen-apposing metal stent (LAMS) has recently been developed specifically for the drainage of pancreatic fluid collections that shows promising results. However, no cost-effectiveness data have been published in comparison with endoscopic drainage with traditional plastic stents (PSs). Our aim here was to compare the cost-effectiveness of LAMSs to PSs in the management of WON.

Methods

A decision tree was developed to assess both LAMSs and PSs over a 6-month time horizon. For each strategy, after the insertion of the respective stents, patients were followed for subsequent need for direct endoscopic necrosectomy, adverse events requiring unplanned endoscopy, percutaneous drainage (PCD), or surgery using probabilities obtained from the literature. The unit of effectiveness was defined as successful endoscopic drainage without the need for PCD or surgery. Costs in 2016 U.S.$ were based on inpatient institutional costs. Sensitivity analyses were performed. An a priori willingness-to-pay threshold of U.S.$50,000 was established.

Results

LAMSs were found to be more efficacious than PSs, with 92% and 84%, respectively, of the patients achieving successful endoscopic drainage of WON. LAMSs, however, were more costly: the average cost per patient of U.S.$20,029 compared with U.S.$15,941 for PSs. The incremental cost-effectiveness ratio favored LAMSs at U.S.$49,214 per additional patient successfully treated. Sensitivity analyses confirmed the robustness of the results.

Conclusion

LAMSs are more effective but also more costly than PSs in managing WON. Data from high-quality, adequately controlled, prospective, randomized trials are needed to confirm our findings.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Abbreviations : ICER, LAMS, LOS, PS, PCD, WON, WTP


Plan


 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: Y.-I. Chen, V. Kumbhari, A. Repici: Consultant for Boston Scientific. A. N. Barkun: Consultant for and research support recipient from Cook Inc, Pendopharm Inc, and Olympus; advisory committee member for Olympus. V. K. Singh: Consultant for Abbvie, Akcea Therapeutics, and Ariel Precision Medicine. M. A. Khashab: Consultant for Boston Scientific and Medtronic; medical advisory board member for Boston Scientific. All other authors disclosed no financial relationships relevant to this publication.


© 2018  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 88 - N° 2

P. 267 - août 2018 Retour au numéro
Article précédent Article précédent
  • A pilot single-center prospective randomized trial to assess the short-term effect of a flashing warning light on reducing fluoroscopy time and radiation exposure during ERCP
  • Hong-Ze Zeng, Qin Liu, Hong-Lin Chen, Wei Liu, Qi-Shan Zeng, Chun-Cheng Wu, Bing Hu
| Article suivant Article suivant
  • Efficacy of EUS-guided and ERCP-guided biliary drainage for malignant biliary obstruction: prospective randomized controlled study
  • Joo Kyung Park, Young Sik Woo, Dong Hyo Noh, Ju-Il Yang, So Young Bae, Hwan Sic Yun, Jong Kyun Lee, Kyu Taek Lee, Kwang Hyuck Lee

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.