Enhanced Ectasia Detection Using Corneal Tomography and Biomechanics - 09/12/18

Doi : 10.1016/j.ajo.2018.08.054 
José Ferreira-Mendes a, b, c, d, Bernardo T. Lopes a, e, f, Fernando Faria-Correia a, b, c, d, Marcella Q. Salomão a, e, f, g, Sandra Rodrigues-Barros h, Renato Ambrósio a, e, f, i,
a Rio de Janeiro Corneal Tomography and Biomechanics Study Group, Rio de Janeiro, Brazil 
b Ophthalmology Department, Hospital de Braga, Braga, Portugal 
c Life and Health Sciences Research Institute (ICVS), School of Health Sciences, University of Minho, Braga, Portugal 
d ICVS/3B's - PT Government Associate Laboratory, Braga/Guimarães, Portugal 
e Instituto de Olhos Renato Ambrósio, Rio de Janeiro, Brazil 
f Department of Ophthalmology and Visual Sciences, Federal University of São Paulo, São Paulo, Brazil 
g Barra Vision Center, Rio de Janeiro, Brazil 
h Hospital Garcia de Orta, Almada, Portugal 
i Department of Ophthalmology, Federal University of the State of Rio de Janeiro, Rio de Janeiro, Brazil 

Inquiries to Renato Ambrósio Jr, Instituto de Olhos Renato Ambrósio, Rua Conde de Bonfim 211/712, Rio de Janerio, RJ, 20.520-050, BrazilInstituto de Olhos Renato AmbrósioRua Conde de Bonfim 211/712Rio de JanerioRJ20.520-050Brazil

Abstract

Purpose

To test the accuracy of the Tomographic and Biomechanical Index (TBI) for ectasia detection in an independent population from the original study.

Design

Retrospective case-control study.

Methods

Subjects: Patients were grouped according to clinical diagnosis including corneal topography (front-surface curvature): Normal group, including 1 eye randomly selected from 312 patients with normal corneas; Keratoconus group, including 1 eye randomly selected from 118 patients with keratoconus; a nonoperated ectatic eye from 57 patients with very asymmetric ectasia (57 eyes, VAE-E group), and the nonoperated fellow eye with normal topography (57 eyes, VAE-NT group). Main Outcome Measures: The ability of TBI to distinguish normal and ectatic corneas; and comparison with other indexes, including the Belin/Ambrósio Deviation Index (BAD-DI) and the Corvis Biomechanical Index (CBI), considering the areas under receiver operating characteristic curves (AUCs).

Results

The AUC of the TBI was statistically higher than all other tested parameters (DeLong, P < .001). Considering all cases, the cut-off value of 0.335 for the TBI provided a sensitivity of 94.4% and a specificity of 94.9% (AUC = 0.988; 95% confidence interval [CI] 0.982–0.995). Considering the VAE-NT group, optimized TBI cut-off value of 0.295 provided a sensitivity of 89.5% and a specificity of 91.0% (AUC = 0.960; 95% CI 0.937–0.983).

Conclusion

The TBI was more accurate than all parameters tested for differentiating normal from ectatic corneas. The TBI may epitomize ectasia susceptibility and distinguish cases with fruste disease from true unilateral cases among the eyes with normal-topography VAE.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2018  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 197

P. 7-16 - janvier 2019 Retour au numéro
Article précédent Article précédent
  • Avoiding Hyperopic Surprises After Descemet Membrane Endothelial Keratoplasty in Fuchs Dystrophy Eyes by Assessing Corneal Shape
  • Marianne Fritz, Viviane Grewing, Daniel Böhringer, Thabo Lapp, Philip Maier, Thomas Reinhard, Katrin Wacker
| Article suivant Article suivant
  • Moraxella Keratitis: Analysis of Risk Factors, Clinical Characteristics, Management, and Treatment Outcomes
  • Asad F. Durrani, Samuel C. Faith, Regis P. Kowalski, Marco Yu, Eric Romanowski, Robert Shanks, Deepinder Dhaliwal, Vishal Jhanji

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.