S'abonner

Allograft rejection is associated with development of functional IgE specific for donor MHC antigens - 04/01/19

Doi : 10.1016/j.jaci.2018.06.034 
Andreas M. Farkas, MSc a, Ulrike Baranyi, PhD a, b, Georg A. Böhmig, MD c, Lukas Unger, MD a, Stefan Hopf, MSc a, Markus Wahrmann, PhD c, Heinz Regele, MD d, Benedikt Mahr, PhD a, Christoph Schwarz, MD, PhD a, Karin Hock, PhD a, Nina Pilat, PhD a, Ivan Kristo, MD a, Jasmin Mraz, MSc a, Christian Lupinek, MD e, Josef Thalhamer, PhD f, Gregor Bond, MD, PhD c, Lorenz Kuessel, MD i, Elizabeth Wlodek, MD g, Jack Martin, MD g, Menna Clatworthy, MD h, Gavin Pettigrew, MD g, Rudolf Valenta, MD e, , Thomas Wekerle, MD a,
a Section of Transplantation Immunology, Department of Surgery, Medical University of Vienna, Vienna, Austria 
b Cardiac Surgery Laboratory, Medical University of Vienna, Vienna, Austria 
c Division of Nephrology and Dialysis, Department of Internal Medicine III, Medical University of Vienna, Vienna, Austria 
d Institute of Clinical Pathology, Medical University of Vienna, Vienna, Austria 
e Division of Immunopathology, Department of Pathophysiology and Allergy Research, Center of Physiology and Pathophysiology, Infectiology and Immunology, Medical University of Vienna, Vienna, Austria 
i Department for Obstetrics and Gynecology, Medical University of Vienna, Vienna, Austria 
f Department of Molecular Biology, University of Salzburg, Salzburg, Austria 
g Department of Surgery, University of Cambridge, Cambridge, United Kingdom 
h Department of Medicine, University of Cambridge, Cambridge, United Kingdom 

Corresponding author: Thomas Wekerle, MD, Section of Transplantation Immunology, Department of Surgery, Medical University of Vienna, Waehringer Guertel 18, 1090 Vienna, Austria.Section of Transplantation ImmunologyDepartment of SurgeryMedical University of ViennaWaehringer Guertel 18Vienna1090Austria

Abstract

Background

Donor-specific antibodies of the IgG isotype are measured routinely for diagnostic purposes in renal transplant recipients and are associated with antibody-mediated rejection and long-term graft loss.

Objective

This study aimed to investigate whether MHC-specific antibodies of the IgE isotype are induced during allograft rejection.

Methods

Anti-MHC/HLA IgE levels were measured in sera of mice grafted with skin or heart transplants from various donor strains and in sera of kidney transplant patients with high levels of HLA IgG. Mediator release was triggered in vitro by stimulating basophils that were coated with murine or human IgE-positive serum, respectively, with specific recombinant MHC/HLA antigens. Kidney tissue samples obtained from organ donors were analyzed by using flow cytometry for cells expressing the high-affinity receptor for IgE (FcεRI).

Results

Donor MHC class I– and MHC class II–specific IgE was found on acute rejection of skin and heart grafts in several murine strain combinations, as well as during chronic antibody-mediated heart graft rejection. Anti-HLA IgE, including donor HLA class I and II specificities, was identified in a group of sensitized transplant recipients. Murine and human anti-MHC/HLA IgE triggered mediator release in coated basophils on stimulation with specific MHC/HLA antigens. HLA-specific IgE was not linked to atopy, and allergen-specific IgE present in allergic patients did not cross-react with HLA antigens. FcεRI+ cells were found in the human renal cortex and medulla and provide targets for HLA-specific IgE.

Conclusion

These results demonstrate that MHC/HLA-specific IgE develops during an alloresponse and is functional in mediating effector mechanisms.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Key words : Transplantation, immunology, alloreactivity, humoral rejection, IgE, donor-specific antibodies

Abbreviations used : ABMR, DSA, HRP, MFI, PE, RBL, SAB


Plan


 Supported by the Austrian Science Fund (FWF; projects TRP151-B19 and W1212 to T.W., project P21989-B11 to U.B, and project F4605 to R.V.) and the Medical Scientific Fund of the Mayor of the City of Vienna (project 13051 to T.W.). R.V. is recipient of a Megagrant of the Government of the Russian Federation (grant no. 14.W03.31.0024).
 Disclosure of potential conflict of interest: R. Valenta has received research grants from Biomay AG and Viravaxx and serves as a consultant for both companies. The rest of the other authors declare that they have no relevant conflicts of interest to disclose.


© 2018  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 143 - N° 1

P. 335 - janvier 2019 Retour au numéro
Article précédent Article précédent
  • PROMIDIS?: A T-cell receptor ? signature associated with immunodeficiencies caused by V(D)J recombination defects
  • Aurélie Berland, Jérémie Rosain, Sophie Kaltenbach, Vincent Allain, Nizar Mahlaoui, Isabelle Melki, Alice Fievet, Catherine Dubois d'Enghien, Marie Ouachée-Chardin, Laurence Perrin, Nathalie Auger, Funda Erol Cipe, Andrea Finocchi, Figen Dogu, Felipe Suarez, Despina Moshous, Thierry Leblanc, Alexandre Belot, Claire Fieschi, David Boutboul, Marion Malphettes, Lionel Galicier, Eric Oksenhendler, Stéphane Blanche, Alain Fischer, Patrick Revy, Dominique Stoppa-Lyonnet, Capucine Picard, Jean-Pierre de Villartay
| Article suivant Article suivant
  • Education-dependent activation of glycolysis promotes the cytolytic potency of licensed human natural killer cells
  • Jolie R. Schafer, Travis C. Salzillo, Nitin Chakravarti, Meisam Naeimi Kararoudi, Prashant Trikha, Jennifer A. Foltz, Ruoning Wang, Shulin Li, Dean A. Lee

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.