BioMonitor 2 Pilot Study: Early Experience With Implantation of the Biotronik BioMonitor 2 Implantable Cardiac Monitor - 25/01/19

Doi : 10.1016/j.hlc.2017.09.005 
Sze-Yuan Ooi, MBBS, MD, FRACP a, b, , Ben Ng, MBBS, FRACP a, b, Suresh Singarayar, MBBS, PhD, FRACP a, b, Kevin Hellestrand, MBBS, PhD, FRACP c, Peter Illes, MBBS, FRACP c, Uwais Mohamed, MBBS, FRACP d, Shakeeb Razak, MBBS, FRACP e, Rukshen Weerasooriya, MBBS, FRACP f, g

for the BioMonitor 2 Study Investigators

a Prince of Wales Hospital and Eastern Heart Clinic, Sydney, NSW, Australia 
b University of New South Wales, Sydney, NSW, Australia 
c Sydney Adventist Hospital, Sydney, NSW, Australia 
d Northern Hospital, Melbourne, Vic, Australia 
e Joondalup Health Campus, Perth, WA, Australia 
f Hollywood Private Hospital, Perth, WA, Australia 
g University of Western Australia, Perth, WA, Australia 

Corresponding author at: Department of Cardiology, Level 3, Clinical Sciences Building, Prince of Wales Hospital, Randwick, NSW 2032, Australia. Tel.: +61 2 9382 0770, Fax: +61 2 9382 0799.Department of CardiologyLevel 3, Clinical Sciences Building, Prince of Wales HospitalRandwickNSW2032Australia

Résumé

Background

The BioMonitor 2 Pilot Study assessed the implantation procedure, the sensing amplitude and the remote monitoring transmission success rate of the second generation implantable cardiac monitor, the BioMonitor 2 (Biotronik, Berlin, Germany).

Methods

This was a prospective, multi-centre, single-arm, non-randomised study involving seven operators in five sites across Australia. Data were collected at implantation, during clinic visits at 1 week and 1 month post-implantation, and through wireless remote monitoring.

Results

Thirty patients with indications for long-term cardiac monitoring underwent successful insertion of a study device. The median implantation time was 9 minutes (interquartile range (IQR) 5–14 mins). The mean R-wave amplitude at 1 week was 0.75±0.39mV and remained stable over the follow-up period. Within 1 day, 97% of the patients connected to the remote monitoring network and daily messages were transmitted on 93.8% of all study days. Seventy-six per cent of patients transmitted at least one subcutaneous ECG (sECG), with a median number of sECGs per patient of seven (IQR 3–37) within 28 days.

Conclusions

The results of the BioMonitor 2 Pilot study confirm the excellent sensing amplitudes afforded by this new device and the utility of the implantation tools and technique. Patient compliance with and the transmission success rate of the home monitoring system were excellent.

Le texte complet de cet article est disponible en PDF.

Keywords : Remote monitoring, Syncope, Arrhythmia


Plan


 Clinical trial registration: Australian New Zealand Clinical Trials Registry ID: ACTRN12614001266651.


© 2017  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 27 - N° 12

P. 1462-1466 - décembre 2018 Retour au numéro
Article précédent Article précédent
  • Evaluation of Cognitive Function Following Transcatheter Aortic Valve Replacement
  • Masieh Abawi, Rehana de Vries, Pieter R. Stella, Pierfrancesco Agostoni, Dirk H.M. Boelens, Romy C. van Jaarsveld, Charlotte S. van Dongen, Pieter A.F.M. Doevendans, Mariëlle H. Emmelot-Vonk
| Article suivant Article suivant
  • Th17/Treg Ratio in Serum Predicts Onset of Postoperative Atrial Fibrillation After Off-Pump Coronary Artery Bypass Graft Surgery
  • Yi He, Xi Chen, Xuejun Guo, Hang Yin, Nan Ma, Min Tang, Hao Liu, Ju Mei

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.