S'abonner

Changes in Ganglion Cell–Inner Plexiform Layer Thickness and Retinal Microvasculature in Hypertension: An Optical Coherence Tomography Angiography Study - 21/02/19

Doi : 10.1016/j.ajo.2018.11.016 
Hyung Bin Lim a, c, Min Woo Lee a, Jae Hyeong Park b, Kyeungmin Kim a, Young Joon Jo a, Jung Yeul Kim a,
a Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, South Korea 
b Division of Cardiology, Department of Internal Medicine, Chungnam National University College of Medicine, Daejeon, South Korea 
c Department of Ophthalmology, Armed Forces Capital Hospital, Seongnam, South Korea 

Inquiries to Jung-Yeul Kim, Department of Ophthalmology, Chungnam National University Hospital, #640 Daesa-dong, Jung-gu, Daejeon 35015, South KoreaDepartment of OphthalmologyChungnam National University Hospital#640 Daesa-dong, Jung-guDaejeon35015South Korea

Abstract

Purpose

To investigate retinal blood flow in patients with hypertension using optical coherence tomography angiography (OCTA) and the relationship between blood flow metrics and ganglion cell–inner plexiform layer (GC-IPL) thickness.

Design

Retrospective, cross-sectional study.

Methods

A total of 201 eyes from 117 healthy subjects and 84 hypertensive patients without any ocular abnormalities were included. Hypertensive patients were divided into the 2 groups according to disease periods (<5 years: Hypertension Group 1; ≥5 years: Hypertension Group 2). Macular 3 × 3-mm angiography was acquired using the Zeiss Cirrus 5000 OCT instrument. Vessel density (VD), perfusion density (PD), and foveal avascular zone metrics of the superficial capillary plexus were automatically calculated, and the thicknesses of the central fovea, GC-IPL, and peripapillary retinal nerve fiber layer (RNFL) were measured. All measurements were compared among the 3 groups, and retinal blood flow metrics were correlated with the thickness of each retinal layer. Logistic regression analyses were performed to determine the factors associated with prolonged hypertension.

Results

The average GC-IPL (P < .001) and peripapillary RNFL (P = .048) thicknesses in Hypertension Group 2 were significantly thinner compared to the control group. The 3 mm total area of the VD and PD was also decreased compared to the control group and Hypertension Group 1 (all P < .05), and was significantly correlated with the GC-IPL (VD: r = 0.450, P = .001; PD: r = 0.467, P < .001) and peripapillary RNFL (VD: r = 0.314, P = .027; PD: r = 0.328, P = .023) thicknesses in Hypertension Group 2. Using multivariate logistic analyses, only the average GC-IPL thickness was a significant factor for prolonged hypertension (odds ratio = 0.911, P = .002).

Conclusions

In patients with hypertension lasting more than 5 years, inner retinal layer thinning, particularly GC-IPL thinning, was observed, which was significantly correlated with a decrease in retinal blood flow. Therefore, physicians should consider the effects of hypertension on the GC-IPL.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2018  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 199

P. 167-176 - mars 2019 Retour au numéro
Article précédent Article précédent
  • Residual Iris Retraction Syndrome After Artificial Iris Implantation
  • Christian S. Mayer, Andrea E. Laubichler, Michael Masyk, Philipp Prahs, Daniel Zapp, Ramin Khoramnia
| Article suivant Article suivant
  • Automated Detection of the Stromal Demarcation Line Using Optical Coherence Tomography in Keratoconus Eyes After Corneal Cross-linking
  • Shady T. Awwad, Maamoun Abdul Fattah, Manal Shokr, Ahmad R. Dhaini

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.