Minimizing central line–associated bloodstream infections in a high-acuity liver transplant intensive care unit - 28/02/19

Doi : 10.1016/j.ajic.2018.08.006 
Tara A Russell, MD, MPH, PhD a, b, Elyse Fritschel, MPH, CIC c, Jennifer Do, MSN, RN, ACNP d, Melanie Donovan, RN, BSN d, Maureen Keckeisen, RN, MN d, Vatche G. Agopian, MD d, Douglas G. Farmer, MD d, Tisha Wang, MD e, Zachary Rubin, MD f, Ronald W. Busuttil, MD, PhD d, Fady M. Kaldas, MD d,
a Department of General Surgery, University of California Los Angeles, Los Angeles, CA 
b Veterans Affairs Health Services Research & Development Center for the Study of Healthcare Innovation, Implementation & Policy, Department of Veterans Affairs,Los Angeles, CA 
c Clinical Epidemiology and Infection Prevention, UCLA Ronald Reagan Medical Center, Los Angeles, CA 
d Division of Liver and Pancreas Transplantation, Department of General Surgery, University of California Los Angeles, Los Angeles, CA 
e Division of Pulmonary and Critical Care Medicine, Department of General Internal Medicine, University of California Los Angeles, Los Angeles, CA 
f Division of Infectious Diseases, Department of General Internal Medicine, University of California Los Angeles, Los Angeles, CA 

Address correspondence to Fady M. Kaldas, MD, 757 Westwood Plaza, Suite 8501, Los Angeles, CA 90095.757 Westwood Plaza, Suite 8501Los AngelesCA90095

Résumé

Background

Increases in liver transplant patient perioperative acuity have resulted in frail immunosuppressed patients at elevated risk for nosocomial infections. Avoiding central line–associated bloodstream infections (CLABSIs) is paramount to facilitate transplantation and post-transplant recovery. In 2015, our liver transplant intensive care unit (ICU) CLABSIs accounted for more than 25% of all CLABSI at our institution. We therefore undertook a multidisciplinary collaborative among clinical epidemiology, nursing, transplant surgery, and critical care to eliminate CLABSI events.

Methods

From 2014-2016, using Lean methodology and plan-do-study-act (PDSA) cycles, 14 interventions were implemented in the liver transplant ICU. Interventions were aimed at infection prevention, care standardization, and team-based monitoring. Implementation used quality improvement methodology including audit and feedback, education, standardization, multidisciplinary stakeholder involvement, and PDSA cycles. Process measures were monitored and audited. CLABSI rates per 1,000 central venous catheter (CVC) days were tracked by clinical epidemiology.

Results

During the intervention, 901 CVC catheter audits were completed. Improvements were seen on all process measures, and complete compliance increased from 25%-67%. CLABSI infection rates dropped from 4.2 to 1.8 in 1,000 CVC days, with an average of less than 1 CLABSI per month. This marked a 61.2% annual reduction, which correlated with an estimated $935,000 annual savings.

Conclusion

Concerted ongoing multidisciplinary collaboratives are essential to minimize CLABSI and optimize value and quality in a challenging, high-acuity patient population.

Le texte complet de cet article est disponible en PDF.

Key Words : Central line–associated bloodstream infection, Intensive care unit, Liver transplant, Transplantation, Lean methodology, PDSA


Plan


 Previous presentation: Presented at the American College of Surgeons Annual Congress, San Diego, California, October 22-26, 2017.
 Funding/support: T.A.R. was supported by the VA Office of Academic Affiliation through the Veterans Affairs Robert Wood Johnson Clinical Scholars Program.
 Conflicts of interest: None to report.


© 2018  Association for Professionals in Infection Control and Epidemiology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 47 - N° 3

P. 305-312 - mars 2019 Retour au numéro
Article précédent Article précédent
  • A novel personal protective equipment coverall was rated higher than standard Ebola virus personal protective equipment in terms of comfort, mobility and perception of safety when tested by health care workers in Liberia and in a United States biocontainment unit
  • Brian T. Garibaldi, Chandrakant Ruparelia, Kathryn Shaw-Saliba, Lauren M. Sauer, Lisa L. Maragakis, Margaret Glancey, Marion Subah, Allyson R. Nelson, Colby Wilkason, Laura Scavo, Lindsay Litwin, Patience Osei, Youseph Yazdi
| Article suivant Article suivant
  • Validity of hand hygiene compliance measurement by observation: A systematic review
  • Annette Jeanes, Pietro G. Coen, Dinah J. Gould, Nicolas S. Drey

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.