Corneal Epithelial Thickness Intrasubject Repeatability and its Relation With Visual Limitation in Keratoconus - 30/03/19

Doi : 10.1016/j.ajo.2019.01.015 
Alfredo Vega-Estrada a, b, c, , Michael Mimouni d, e, Elias Espla a, Jorge Alió del Barrio a, b, c, Jorge L. Alio a, b, c
a Department of Cornea and Refractive Surgery, Vissum, Alicante, Spain 
b Keratoconus Unit of Vissum, Alicante, Spain 
c Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain 
d Department of Ophthalmology, Rambam Health Care Campus, Haifa, Israel 
e The Ruth and Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel 

Inquiries to Alfredo Vega-Estrada, Vissum Alicante, Calle Cabañal, 1 03016 Alicante, SpainVissum AlicanteCalle Cabañal, 1Alicante03016Spain

Abstract

Purpose

To evaluate intra-subject repeatability of anterior segment optical coherence tomography (AS-OCT) combined with placido disc MS-39 (CSO, Firenze, Italy) and correlate epithelial thickness measurements and the degree of visual limitation in keratoconus patients.

Design

Reliability analysis and cross-sectional study.

Methods

Setting: Vissum, Alicante, Spain. Subjects: Total of 167 eyes, of which 107 were from keratoconus patients and 60 were healthy. Procedures: Three repeated consecutive epithelial thickness measurements were taken: central 3.0 mm and the nasal, temporal, superior, and inferior regions at 3.0-6.0 mm and 6.0-8.0 mm. Main Outcome Measures: Intrasubject repeatability of epithelial indices was assessed and correlated to the degree of best-corrected visual acuity (BCVA).

Results

The intraclass correlation coefficient was ≥0.90, indicating highly repeatable measurements for both keratoconus and healthy eyes. In multivariate analysis, epithelial indices associated with worse BCVA were as follows: thinner 3 mm central (P = .04), thicker 8 mm superior (P < .001), and thinner 8 mm inferior (P < .001). Thickness central 3 mm decreased as keratoconus grading increased (P = .002). The superior-inferior ratio at 8 mm significantly increased as keratoconus grading increased (P < .001). In multivariate analysis thinner 3 mm central (R2 = 6.19%, P = .04), greater superior-inferior 8 mm ratio (R2 = 8.37%, P = .004), greater superior-inferior 6mm ratio (R2 = 2.67%, P = .02), and steeper K2 (R2 = 21.51%, P < .001) were associated with keratoconus with a combined area under the curve of 0.92.

Conclusion

High repeatability of epithelial thickness measurements may be achieved in both keratoconus and healthy eyes with the MS-39. There is a significant correlation between epithelial thickness measurements and BCVA. These measurements may be of additional value in discriminating between keratoconus and healthy eyes.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2019  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 200

P. 255-262 - avril 2019 Retour au numéro
Article précédent Article précédent
  • Incidence and Ocular Features of Pediatric Myasthenias
  • Sasha A. Mansukhani, Erick D. Bothun, Nancy N. Diehl, Brian G. Mohney
| Article suivant Article suivant
  • Peripapillary Versus Macular Combined Hamartoma of the Retina and Retinal Pigment Epithelium: Imaging Characteristics
  • Rajan Gupta, Adrian T. Fung, Marco Lupidi, Rajeev R. Pappuru, Sameera Nayak, Niroj Kumar Sahoo, Swathi Kaliki, Lawrence Yannuzzi, Kate Reid, Lianne Lim, Riccardo Sacconi, Vivek Dave, Sumit Randhir Singh, Apoorva Ayachit, Pierre-Henry Gabrielle, Sophie Cai, Luiz H. Lima, Giuseppe Querques, J. Fernando Arevalo, K. Bailey Freund, Carol L. Shields, Jay Chhablani

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.