S'abonner

Predictive Value of Left Ventricular Myocardial Deformation for Left Ventricular Remodeling in Patients With Classical Low-Flow, Low-Gradient Aortic Stenosis Undergoing Transcatheter Aortic Valve Replacement - 04/06/19

Doi : 10.1016/j.echo.2019.03.002 
Antonello D'Andrea, MD, PhD a, b, ⁎ , Andreina Carbone, MD a, Eustachio Agricola, MD c, Lucia Riegler, MD b, Simona Sperlongano, MD a, Giampaolo Tocci, MD a, Raffaella Scarafile, MD b, Tiziana Formisano, MD a, Cristina Capogrosso, MD c, Maurizio Cappelli Bigazzi, MD a, Eduardo Bossone, MD d, Maurizio Galderisi, MD e, Paolo Golino, MD a
a Luigi Vanvitelli University – Naples, Monaldi Hospital, Naples, Italy 
b Department of Cardiology, Umberto I° Hospital Nocera Inferiore, Salerno, Italy 
c San Raffaele Hospital, Milan, Italy 
d University of Salerno, Salerno, Italy 
e Federico II University of Naples, Naples, Italy 

∗Reprint requests: Antonello D'Andrea, MD, PhD, Corso Vittorio Emanuele, 121A, 80121 Naples, Italy.Corso Vittorio Emanuele, 121ANaples80121Italy

Abstract

Background

Transcatheter aortic valve replacement (TAVR) is an alternative treatment in surgically intermediate- or high-risk patients with classical low-flow, low-gradient (LFLG) aortic stenosis (AS). The objective of this study was to investigate whether two-dimensional (2D) speckle-tracking echocardiography (STE) can predict left ventricular (LV) flow reserve during dobutamine stress echocardiography (DSE) and remodeling after TAVR in patients with LFLG AS.

Methods

Seventy-five symptomatic patients with severe LFLG AS were recruited (mean age, 77.6 ± 8.4 years). Patients underwent a complete clinical evaluation, standard echocardiography, 2D STE, and DSE. Echocardiographic analysis was performed before and 6 months after TAVR using global longitudinal strain (GLS) measured on 2D STE.

Results

All patients received self-expanding transcatheter prosthetic valves. Six months after TAVR, LV GLS (12.8 ± 3.2% vs 16.3 ± 4.2%, P < .0001) significantly increased. In a multivariate analysis, LV GLS before TAVR (P < .0001) was an independent predictor of LV flow reserve during DSE. By receiver operating characteristic curve analysis, a cutoff value for LV GLS of ≤12% well distinguished patients without significant flow reserve and with lack of positive remodeling after TAVR at follow-up. These results support the hypothesis that myocardial analysis by 2D STE at baseline can be useful for the identification of patients with LFLG AS who would benefit from TAVR.

Conclusions

The results of this study underline the predictive value of LV GLS on flow reserve during DSE and on global LV remodeling after TAVR in patients with LFLG AS. Cutoff values for LV GLS could be used to identify patients responding better to TAVR.

Le texte complet de cet article est disponible en PDF.

Highlights

•
In patients with classical LFLG AS, there is improvement of LV strain after TAVR.
•
Two-dimensional STE can predict LV flow reserve after TAVR in patients with LFLG AS.
•
A value for LV GLS of −12% identified patients with lack of remodeling after TAVR.

Le texte complet de cet article est disponible en PDF.

Keywords : Aortic stenosis, Low flow, Low gradient, Contractile reserve, Two-dimensional strain, Transcatheter aortic valve replacement

Abbreviations : 2D, AS, DSE, GLS, LAVI, LFLG, LV, LVEF, LVMI, NYHA, STE, TAVR


Plan


 Conflicts of Interest: None.


© 2019  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 32 - N° 6

P. 730-736 - juin 2019 Retour au numéro
Article précédent Article précédent
  • The Association Between Longitudinal Strain at Rest and Stress and Outcome in Asymptomatic Patients With Moderate and Severe Aortic Stenosis
  • Shani Levy-Neuman, Valery Meledin, Gera Gandelman, Sorel Goland, Liaz Zilberman, Orly Edri, Natali Shneider, Naama Abaeh, Tali Bdolah-Abram, Jacob George, Sara Shimoni
| Article suivant Article suivant
  • Prognostic Implications of Baseline Pulmonary Vascular Resistance Determined by Transthoracic Echocardiography Before Transcatheter Aortic Valve Replacement
  • Zach Rozenbaum, Yan Topilsky, Simon Biner, Arie Steinvil, Yaron Arbel, Samuel Bazan, Shmuel Banai, Ariel Finkelstein, Amir Halkin

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.