Normal Reference Values and Reproducibility of Tricuspid Annulus Dimensions Using Cardiovascular Magnetic Resonance - 26/07/19

Doi : 10.1016/j.amjcard.2019.05.019 
Yang Zhan, MD a, Dany Debs, MD a, Mohammad A. Khan, MD a, Duc T. Nguyen, MD, PhD b, Edward A. Graviss, PhD b, c, Dipan J. Shah, MD a,
a Department of Cardiology, Houston Methodist DeBakey Heart & Vascular Center, Houston, Texas 
b Department of Pathology and Genomic Medicine, Houston Methodist Hospital, Houston, Texas 
c Department of Surgery, Houston Methodist Hospital, Houston, Texas 

Corresponding author. Tel: 713-441-3625; fax: 713-791-5500.

Résumé

Tricuspid annular (TA) dilation is a key process in functional tricuspid regurgitation, but normal TA dimensions using cardiovascular magnetic resonance have not been established. We measured TA diameters in 66 healthy volunteers, aged 38 ± 11 years, during 3 different phases of the cardiac cycle (end-systole, early diastole, and end-diastole) and in 2 routinely acquired cardiovascular magnetic resonance imaging planes (4-chamber [4C] and right ventricular inflow-outflow [RVIO]). Three readers independently measured each value and 1 reader repeated measurements 1 month apart. The upper limit of normal (ULN) was calculated as 1.96 standard deviations above the mean. We assessed inter- and intraobserver reliability using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. We found the TA diameter largest during early diastole in the 4C view with an ULN of 43 mm (22 mm/m2). Men had larger absolute TA diameters (36 mm, 95% CI 27 to 44 mm) than women (30 mm, 95% CI 23 to 37 mm) but not after indexing for body surface area (both 18 mm/m2). In the RVIO view, the largest TA diameter occurred during early diastole with a ULN value of 46 mm (27 mm/m2). In this view, females had a larger indexed TA than men (21 mm/m2 vs 17 mm/m2). Reproducibility of measurements was excellent in all cardiac phases with an inter-rater ICC between 0.90 to 0.96 and an intrarater ICC 0.89 to 0.96. In conclusion, we have provided normative data regarding TA dimensions in routinely acquired 4C and RVIO views, and these values are larger than the current thresholds of annular dilation measured by echocardiography. Gender differences with the TA diameter in the RVIO view may be an important finding with consideration of future tricuspid devices.

Le texte complet de cet article est disponible en PDF.

Plan


© 2019  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 124 - N° 4

P. 594-598 - août 2019 Retour au numéro
Article précédent Article précédent
  • The Outcomes of Pulmonary Hypertension Patients With Severe Aortic Stenosis Who Underwent Surgical Aortic Valve Replacement or Transcatheter Aortic Valve Implantation
  • Yasser Al-khadra, Fahed Darmoch, Homam Moussa Pacha, Mohamad Soud, Marvin Kajy, Tomo Ando, Tanveer Rab, Cindy L. Grines, Amir Kaki, Chun Shing Kwok, Mamas A. Mamas, James J. Glazier, M. Chadi Alraies
| Article suivant Article suivant
  • Comparison of Clinical and Morphologic Findings in Patients With Cardiac Sarcoidosis Severe Enough to Warrant Heart Transplantation in Those With -vs- Those Without Non-Caseating Granulomas in the Explanted Heart (Burnt-Out Sarcoid)
  • Samreen Fathima, William C. Roberts

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.