Comparative effectiveness of rapid-cycle ultraviolet decontamination to chemical decontamination on high-touch communication devices - 23/08/19

Doi : 10.1016/j.ajic.2019.02.022 
Marisol Resendiz, PhD, Timothy S. Horseman, MS, Michael B. Lustik, MS, Abu Nahid, PhD, Gordon F. West, PhD ⁎
 Tripler Army Medical Center, Honolulu, HI 

⁎Address correspondence to Gordon F. West, 1 Jarrett White Rd, Honolulu, HI 96859.1 Jarrett White Rd HonoluluHI96859

Résumé

Background

This quantitative, comparative-descriptive study of inpatient units in a large military medical center was designed to compare the effectiveness of compact ultraviolet (UV-C) decontamination to standard chemical decontamination in reducing the microbial burden on Vocera (San Jose, CA) communication devices and to characterize changes in staff cleaning practices following UV-C device implementation.

Methods

Aerobic and anaerobic swabs were used to collect microbial samples from Vocera devices (n = 60) before and after chemical decontamination (first sampling) and before and after UV decontamination (second sampling). Cleaning behaviors were assessed by observation and oral inquiry during the baseline sampling and surveyed 8 weeks after UV-C device implementation. Outcomes included aerobic and anaerobic colony-forming units and prevalence of methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, or Clostridium difficile, as determined by standard microbiological methods.

Results

No differences were found between the two cleaning methods in their ability to reduce aerobic bacteria; however, UV-C was significantly more effective at reducing bacteria grown anaerobically (P < .01). This study elucidated an 8.3% prevalence of methicillin-resistant Staphylococcus aureus on Vocera devices in the inpatient environment. Initially, 42% of respondents reported deviations from manufacturer's cleaning guidelines, and 16.7% reported daily or more frequent cleaning of the Vocera devices.

Conclusions

After implementation, UV-C decontamination reduced average cleaning time by 43% and increased the rate of daily Vocera cleaning to 86.5%. Respondents reported an overall 98% user satisfaction with the UV-C device.

Le texte complet de cet article est disponible en PDF.

Key Words : Contamination, Surface decontamination, Ultraviolet


Plan


 Funding/support: We thank the Army Advanced Medical Technology Initiative, Telemedicine and Advanced Technology Research Center, US Army Medical Research and Materiel Command, for funding this research study. The views expressed in this manuscript are those of the authors and do not reflect the official policy or position of the Department of the Army, Department of Defense, or US Government.
 Conflicts of interest: None to report.


© 2019  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 47 - N° 9

P. 1135-1139 - septembre 2019 Retour au numéro
Article précédent Article précédent
  • What do patients say about their experience with urinary catheters and peripherally inserted central catheters?
  • Barbara W. Trautner, Sanjay Saint, Karen E. Fowler, John Van, Tracey Rosen, John Colozzi, Vineet Chopra, Erica Lescinskas, Sarah L. Krein
| Article suivant Article suivant
  • Predictors of mortality in patients infected with carbapenem-resistant Acinetobacter baumannii: A systematic review and meta-analysis
  • Xingran Du, Xinfeng Xu, Jing Yao, Kaili Deng, Sixia Chen, Ziyan Shen, Lihua Yang, Ganzhu Feng

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.