S'abonner

Endoscopists systematically undersample patients with long-segment Barrett’s esophagus: an analysis of biopsy sampling practices from a quality improvement registry - 18/10/19

Doi : 10.1016/j.gie.2019.04.250 
Sachin Wani, MD 1, , J. Lucas Williams, MPH 2, Srinadh Komanduri, MD 3, V. Raman Muthusamy, MD 4, Nicholas J. Shaheen, MD, MPH 5
1 Division of Gastroenterology and Hepatology, University of Colorado School of Medicine, Anschutz Medical Campus, Aurora, Colorado, USA 
2 GI Quality Improvement Consortium, Bethesda, Maryland, USA 
3 Division of Gastroenterology and Hepatology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA 
4 Division of Gastroenterology and Hepatology, University of California, Los Angeles, Los Angeles, California, USA 
5 Division of Gastroenterology and Hepatology, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA 

Reprint requests: Sachin Wani, MD, Division of Gastroenterology and Hepatology, University of Colorado Anschutz Medical Center, Mail Stop F735, 1635 Aurora Court, Rm 2.031, Aurora, CO 80045.Division of Gastroenterology and HepatologyUniversity of Colorado Anschutz Medical CenterMail Stop F7351635 Aurora CourtRm 2.031AuroraCO80045

Abstract

Background and Aims

Guidelines recommend systematic biopsy sampling in Barrett’s esophagus (BE) to reduce sampling error. Adherence to this biopsy sampling protocol has been suggested as a quality indicator; however, estimates of adherence are not available. Using a national registry, we assessed adherence and identified predictors of adherence to biopsy sampling protocols.

Methods

We analyzed data from the GI Quality Improvement Consortium Registry that included procedure indication, demographics, endoscopy, and pathology results. Patients with an indication of BE screening/surveillance or an endoscopic finding of BE were included. Adherence to the Seattle protocol was assessed by dividing BE length by number of pathology jars, with a ratio ≤2.0 with rounding down (lenient definition) or rounding up (stringent definition) for odd BE lengths considered adherent. Variables associated with adherence were assessed using generalized estimating equations to control for clustering within individual physicians.

Results

Of 786,712 EGDs assessed, 58,709 (7.5%) EGDs in 53,541 patients met inclusion criteria (mean age, 61.3 years; 60.4% men; 90.2% white; mean BE length, 2.3 cm). When the lenient and stringent definitions for adherence were used, 87.8% and 82.7% of EGDs were adherent, respectively. Increasing BE length was the most significant predictor of nonadherence (odds ratio, .69; 95% confidence interval, .67-.71). Other predictors were increasing age, male gender, increasing American Society of Anesthesiologists class, and practice location. Performance of EGD by nongastroenterologist physicians was associated with nonadherence (odds ratio, .07; 95% confidence interval, .06-.10).

Conclusions

Nearly 20% of endoscopies performed in BE patients were not adherent to the Seattle protocol. As BE length increases, endoscopists become less compliant with odds of nonadherence increasing by 31% with every 1-cm increase in length.

Le texte complet de cet article est disponible en PDF.

Abbreviations : ASA, BE, CI, EAC, GIQuIC, HGD, LGD


Plan


 DISCLOSURE: The following author received research support for this study from the University of Colorado Department of Medicine Outstanding Early Scholars Program: S. Wani. In addition, the following authors disclosed financial relationships relevant to this publication: S. Wani, S. Komanduri, V. R. Muthusamy: Consultant for Boston Scientific and Medtronic. N. J. Shaheen: Research grants from CDx Medical, Medtronic, C2 Therapeutics, CSA Medical, and Interspace Diagnostics; consultant for Shire and Boston Scientific. All other authors disclosed no financial relationships relevant to this publication.
 See CME section; p. 846.
 If you would like to chat with an author of this article, you may contact Dr Wani at sachinwani10@yahoo.com.


© 2019  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 90 - N° 5

P. 732 - novembre 2019 Retour au numéro
Article précédent Article précédent
  • Improving serrated adenoma detection rate in the colon by electronic chromoendoscopy and distal attachment: systematic review and meta-analysis
  • Muhammad Aziz, Madhav Desai, Seemeen Hassan, Rawish Fatima, Chandra S. Dasari, Viveksandeep Thoguluva Chandrasekar, Ramprasad Jegadeesan, Abhiram Duvvuri, Harsh Patel, Tarun Rai, Anjana Sathyamurthy, Divyanshoo R. Kohli, Prashanth Vennalaganti, Ali Nawras, Michael Wallace, Prateek Sharma
| Article suivant Article suivant
  • Dysplasia detection in Barrett's esophagus: Is the glass half full or half empty?
  • Prasad G. Iyer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.