S'abonner

EUS-guided core liver biopsy sampling using a 22-gauge fork-tip needle: a prospective blinded trial for histologic and lipidomic evaluation in nonalcoholic fatty liver disease - 20/11/19

Doi : 10.1016/j.gie.2019.08.006 
Fateh Bazerbachi, MD 1, Eric J. Vargas, MD 2, Reem Matar 2, Andrew C. Storm, MD 2, Taofic M. Mounajjed, MD 3, Mark D. Topazian, MD 2, Michael J. Levy, MD 2, Vinay Chandrasekhara, MD 2, Barham K. Abu Dayyeh, MD, MPH, FASGE 2,
1 Division of Gastroenterology, Interventional Endoscopy Program, Harvard Medical School and Massachusetts General Hospital, Boston, Massachusetts, USA 
2 Division of Gastroenterology and Hepatology, Mayo Clinic, Rochester, Minnesota, USA 
3 Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, USA 

Reprint requests: Barham K. Abu Dayyeh, MD, MPH, Division of Gastroenterology and Hepatology, Mayo Clinic, 200 First St SW, Rochester, MN 55905.Division of Gastroenterology and HepatologyMayo Clinic200 First St SWRochesterMN55905

Abstract

Background and Aims

Diagnostic tools for nonalcoholic fatty liver disease (NAFLD) detection and prognostication are limited, with histology remaining the criterion standard. We evaluated the feasibility and safety of EUS-guided liver biopsy (EUS-LB) sampling in NAFLD staging.

Methods

In a prospective cohort of NAFLD patients with steatohepatitis and early liver fibrosis based on magnetic resonance elastography (MRE), EUS-LB sampling procedures were performed using a 22-gauge fork-tip core biopsy needle. Samples were evaluated by a blinded pathologist. Total aggregate sample length (TASL), number of complete portal triads, ability to calculate NAFLD activity score, ability to stage liver fibrosis, and ability to provide enough core liver tissue for lipidomics analysis were evaluated. Performance of EUS-LB sampling was compared with MRE.

Results

Forty-one EUS-LB samples were obtained. The median TASL was 2.4 cm (interquartile range, 2.00-2.75). The median number of complete portal triads per TASL was 26 (interquartile range, 7-62). Of the samples, 100% were adequate to convey NAFLD activity score and fibrosis stage. All samples provided enough core liver tissue to allow the application of lipidomics testing. A significant positive linear association between EUS-LB sampling–detected fibrosis and MRE-detected fibrosis was observed (r = .469, P < .005). Compared with MRE, EUS-LB sampling established early fibrosis in 13 cases that MRE classified as normal. EUS-LB sampling–related adverse events occurred in 7% and were restricted to postprocedural pain.

Conclusions

EUS-LB sampling is a viable technique for full NAFLD evaluation and may be superior to MRE in establishing the diagnosis of nonalcoholic steatohepatitis with early fibrosis. (Clinical trial registration number: NCT02880189.)

Le texte complet de cet article est disponible en PDF.

Abbreviations : CPT, EUS-LB, FNB, MRE, NAFLD, NASH, TASL


Plan


 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: B. K. Abu Dayyeh: Research support from Medtronic; A. C. Storm: Consultant for GI Dynamics, Enod-TAGSS, research support from Boston Scientific, Apollo Endosurgery. All other authors disclosed no financial relationships relevant to this publication. Research support for this study was provided by Medtronic (provided needles) and John Derry Endowment.
 See CME section; p. 971.
 If you would like to chat with an author of this article, you may contact Dr Abu Dayyeh at abudayyeh.barham@mayo.edu.


© 2019  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 90 - N° 6

P. 926-932 - décembre 2019 Retour au numéro
Article précédent Article précédent
  • Functional luminal imaging probe: an evolving technology for the diagnosis of esophageal motility disorders
  • Kenneth R. DeVault
| Article suivant Article suivant
  • Association between macroscopically visible tissue samples and diagnostic accuracy of EUS-guided through-the-needle microforceps biopsy sampling of pancreatic cystic lesions
  • Stefano Francesco Crinò, Laura Bernardoni, Lorenzo Brozzi, Luca Barresi, Giuseppe Malleo, Roberto Salvia, Luca Frulloni, Sokol Sina, Alice Parisi, Andrea Remo, Alberto Larghi, Armando Gabbrielli, Erminia Manfrin

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.