S'abonner

How reproducible are classical and new CT-pelvimetry measurements? - 26/01/20

Doi : 10.1016/j.diii.2019.07.011 
C. Capelle a, , P. Devos b, C. Caudrelier c, P. Verpillat a, T. Fourquet a, P. Puech a, C. Garabedian d, e, L. Lemaitre a
a Department of Radiology (Women imaging), University of Lille, CHU of Lille, Hospital Jeanne de Flandre, 59000 Lille, France 
b EA 2694, Department of Public Health, University of Lille, CHU of Lille, 59000 Lille, France 
c Department of Obstetrics, University of Lille, CHU of Lille, Hospital Jeanne de Flandre, 59000 Lille, France 
d EA 4489, Perinatal Environment and Health, University of Lille, 59000 Lille, France 
e Department of Obstetrics, Hospital Jeanne de Flandre, 59000 Lille, France 

Corresponding author. Department of Radiology (Women imaging), University of Lille, CHU of Lille, Hospital Jeanne de Flandre, avenue Eugène-Avinée, 59000 Lille, France.Department of Radiology (Women imaging), University of Lille, CHU of Lille, Hospital Jeanne de Flandreavenue Eugène-AvinéeLille59000France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

The objective of this study was to assess the reliability and reproducibility of existing and new computed tomography (CT)-pelvimetry measurements.

Material and methods

A retrospective cohort study of 63 women with a mean age of 33.9±5.2 (SD) years (range: 19–49 years) was conducted. Classical pelvimetry measurements were collected including the obstetric conjugate (OC), median transverse diameter (MTD), and interspinous diameter (ISD). Additionally, we used multiplanar reconstruction (MPR) mode to define two oblique planes: inlet pelvic plane (IPP) and mid-pelvic plane (MPP) and measure new pelvic parameters, including anteroposterior (APD), transverse diameters and circumference of both IPP and MPP (inletAPD, inletMTD, inletCIRC and midAPD, ISD, midCIRC, respectively). The reproducibility (intra- and inter-observer) of our results were assessed. Multivariate analyses using principal component analysis and clustering methods were conducted to analyze the association between pelvimetry measurements and identify patient sub-groups.

Results

All linear measurements (OC, inletAPD, MTD, inletMTD, midAPD, and ISD) showed statistically “almost perfect” intra- and inter-observer correlation coefficients (range: 0.924–0.980). Circumferences (inletCIRC and midCIRC) showed statistically “almost perfect” intra- (range: 0.847–0.857) and inter-observer correlation coefficients (range: 0.923–0.957). The measurement of 6 pelvimetric parameters allowed determining three groups of pelvis size.

Conclusion

New pelvic measurements have excellent reproducibility and are similar to the classical measurements, based on the MPR analysis of CT planes adjusted to the inner bony pelvis.

Le texte complet de cet article est disponible en PDF.

Keywords : Pelvimetry, Multidetector computed tomography (MDCT), Pregnancy, Reference values, Reproducibility study


Plan


© 2019  Société française de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 2

P. 79-89 - février 2020 Retour au numéro
Article précédent Article précédent
  • Feasibility of two-dimensional ultrasound shear wave elastography of human fetal lungs and liver: A pilot study
  • N. Mottet, C. Cochet, C. Vidal, J.P. Metz, S. Aubry, A. Bourtembourg, A. Eckman-Lacroix, D. Riethmuller, L. Pazart, R. Ramanah
| Article suivant Article suivant
  • Performance of deep learning for differentiating pancreatic diseases on contrast-enhanced magnetic resonance imaging: A preliminary study
  • X. Gao, X. Wang

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.