S'abonner

Comparative finite element analysis of three implants fixing stable and unstable subtrochanteric femoral fractures: Proximal Femoral Nail Antirotation (PFNA), Proximal Femoral Locking Plate (PFLP), and Reverse Less Invasive Stabilization System (LISS) - 30/01/20

Doi : 10.1016/j.otsr.2019.04.027 
Jie Wang a, b, Jian-Xiong Ma b, Bin Lu b, Hao-Hao Bai b, Ying Wang b, Xin-Long Ma a,
a Department of Orthopaedics, Tianjin Medical University General Hospital, No. 154, Anshan Street, Heping District, 300052, Tianjin China 
b Institute of Orthopaedics, Tianjin Hospital, No. 406, Jiefang Nan Street, Hexi District, 300211 Tianjin, China 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

The optimal type of fixation implant for managing subtrochanteric fractures (STFs) is debated, as uncertainty continues to surround the comparative biomechanical performance of the proximal femoral nail antirotation (PFNA), proximal femoral locking plate (PFLP), and reverse less invasive stabilisation system (LISS). No studies have used finite element analysis (FEA) to compare these three devices. The objective of this study was to use FEA to compare the PFNA, PFLP, and LISS used to treat STFs based on the following criteria: (1) stress distribution on the femur and implant, (2) peak stress and stress on the medial side of the femur near the fracture site, and (3) smallest axial displacement of the femoral head.

Hypothesis

Of the three implants, the PFNA has the best biomechanical performance when used for STF fixation.

Methods

FEA was used to assess synthetic bone responses to the three implants used to fix three STF types, namely, Seinsheimer I, III, and IV, characterised by increasing bone loss and/or comminution with subsequent instability. Loading was with 1400N axial compression force.

Results

The LISS and PFLP exhibited similar biomechanical properties in all three fracture types. However, with the Seinsheimer IV fracture, the triangular configuration of the PFLP resulted in stress concentration at the medial and lateral sides of the implant junction. With the Seinsheimer I and III fractures, the PFNA resulted in higher peak stress (183.85MPa and 364.58MPa, respectively) compared to the PFLP (102.90MPa and 177.52MPa) and LISS (116.55MPa and 227.97MPa). With the Seinsheimer IV fracture, peak stress was highest with LISS (2310.40MPa) and was higher with PFLP (2054.90MPa) than with PFNA (1313.30MPa). With the Seinsheimer I and III fractures, the axial femoral head displacement was greater with the PFNA (0.74mm and 1.13mm, respectively) than with the PFLP (0.48mm and 1.02mm) and LISS (0.52mm and 0.92mm). With the Seinsheimer IV fracture, in contrast, the PFNA produced less axial femoral head displacement (4.1mm) compared to the PFLP (12.03mm) and LISS (16.56mm).

Discussion

With unstable (Seinsheimer IV) STFs, fixation stability was better with the PFNA compared to the PFLP and LISS. In contrast, with stable STFs (Seinsheimer I and III), the PFLP and LISS offered greater stability, with similar biomechanical effects. However, with Seinsheimer III fractures, the stress on the implant-femur interface was greater with the LISS.

Level of evidence

IV, basic science study.

Le texte complet de cet article est disponible en PDF.

Keywords : Subtrochanteric fracture, Finite element analysis, Proximal femoral nail antirotation, Less invasive stabilisation system, Proximal femoral locking plate


Plan


© 2019  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 1

P. 95-101 - février 2020 Retour au numéro
Article précédent Article précédent
  • Application of the Radiographic Union Scale for Tibial fractures (RUST): Assessment of healing rate and time of tibial fractures managed with intramedullary nailing
  • Jun Min Leow, Nicholas D. Clement, A. Hamish W.R. Simpson
| Article suivant Article suivant
  • Annual case volume is a risk factor for 30-day unplanned readmission after open reduction and internal fixation of acetabular fractures
  • Robert Kent Merrill, Blake Ryan Turvey, Germanuel Lavar Landfair, Emmanuel Michael Illical

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.