S'abonner

Screening for and decolonization of Staphylococcus aureus carriers before total joint replacement is associated with lower S aureus prosthetic joint infection rates - 23/04/20

Doi : 10.1016/j.ajic.2019.09.022 
Alberto Romero-Palacios, MD, PhD a, Danielle Petruccelli, MSc b, c, Cheryl Main, MD d, c, Mitch Winemaker, MD b, c, Justin de Beer, MD b, c, Dominik Mertz, MD, MSc a, c, d, e,
a Department of Medicine, McMaster University, Hamilton, ON, Canada 
b Department of Surgery, McMaster University, Hamilton, ON, Canada 
c Hamilton Health Sciences, Hamilton, ON, Canada 
d Department of Pathology and Molecular Medicine, McMaster University, Hamilton, ON, Canada 
e Department of Health Research Methods, Evidence and Impact, McMaster University, Hamilton, ON, Canada 

Address correspondence to Dominik Mertz, MD, MSc, Medicine, Clinical Epidemiology and Biostatistics, Juravinski Hospital and Cancer Center, 711 Concession St, Section M, Level 1, Room 3, Hamilton, ON, Canada L8V 1C3.MedicineClinical Epidemiology and BiostatisticsJuravinski Hospital and Cancer Center711 Concession St, Section M, Level 1, Room 3HamiltonONL8V 1C3Canada

Résumé

Background

Prosthetic joint infections (PJI) can be devastating postoperative complications after total joint replacement (TJR). The role of decolonization of Staphylococcus aureus carriers prior to surgery still remains unclear, and the most recent guidelines do not state a formal recommendation for such strategy. Our purpose was to seek further evidence supporting preoperative screening and S aureus decolonization in patients undergoing TJR.

Methods

This was a quasiexperimental quality improvement study comparing a 5-year baseline of deep and organ-space PJIs (2005- 2010) to a 1-year intervention period (May 2015 to July 2016). The intervention consisted of nasal and throat screening for S aureus preoperatively and decolonization of carriers over 5 days prior to surgery.

Results

Prior to the intervention, we identified 42 deep and/or organ-space PJIs in 8,505 patients undergoing TJR (0.5%). S aureus was the causal microorganism in 28 of 42 (66.6%) cases. During the intervention, 22.5% (424 of 1,883) of patients were S aureus carriers. The PJI rate was similar overall (0.4%, 7 of 1,883; odds ratio, 0.75; 95% confidence interval, 0.34-1.67; P = .58), but there was a significant reduction in S aureus PJI to only 1 case during the intervention (odds ratio, 0.15; 95% confidence interval, 0.004-0.94; P = .039).

Conclusions

Active screening for S aureus and decolonization of carriers prior to TJR was associated with a reduction in PJI due to S aureus, but no changes in overall PJI rates were observed.

Le texte complet de cet article est disponible en PDF.

Key Words : Carrier, Preoperative screening, Prosthetic joint infection


Plan


 Funding/support: The study was supported by Hamilton Arthroplasty Group.
 Conflicts of interest: None to report.


© 2019  Association for Professionals in Infection Control and Epidemiology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 48 - N° 5

P. 534-537 - mai 2020 Retour au numéro
Article précédent Article précédent
  • Clinical experiences with a new system for automated hand hygiene monitoring: A prospective observational study
  • Anne-Mette Iversen, Christiane Pahl Kavalaris, Rosa Hansen, Marco Bo Hansen, Rebekah Alexander, Krassimir Kostadinov, Jette Holt, Brian Kristensen, Jenny Dahl Knudsen, Jens Kjølseth Møller, Svend Ellermann-Eriksen
| Article suivant Article suivant
  • Comparison of estimated norovirus infection risk reductions for a single fomite contact scenario with residual and nonresidual hand sanitizers
  • Amanda M. Wilson, Kelly A. Reynolds, Lee-Ann Jaykus, Blanca Escudero-Abarca, Charles P. Gerba

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.