S'abonner

Diabetic Retinopathy Screening Using a Gold Nanoparticle–Based Paper Strip Assay for the At-Home Detection of the Urinary Biomarker 8-Hydroxy-2?-Deoxyguanosine - 08/05/20

Doi : 10.1016/j.ajo.2020.01.032 
Dean P. Hainsworth a, , Abilash Gangula b, Shreya Ghoshdastidar b, Raghuraman Kannan b, Anandhi Upendran c
a Department of Ophthalmology, University of Missouri School of Medicine, Columbia, Missouri, USA 
b Department of Radiology, University of Missouri School of Medicine, Columbia, Missouri, USA 
c University of Missouri Institute of Clinical and Translational Sciences, Department of Pharmacology and Physiology, University of Missouri School of Medicine, Columbia, Missouri, USA 

Inquiries to Dean P. Hainsworth, Department of Ophthalmology, University of Missouri School of Medicine, EC 135, One Hospital Drive, Columbia, MO 65212, USADepartment of OphthalmologyUniversity of Missouri School of MedicineEC 135, One Hospital DriveColumbiaMO65212USA

Abstract

Purpose

We sought to assess a smartphone-based, gold nanoparticle–based colorimetric lateral flow immunoassay paper sensor for quantifying urine 8-hydroxy-2′-deoxyguanosine (8-OHdG) as a biomarker for diabetic retinopathy (DR) screening.

Methods

Paper strips incorporate gold nanoparticle–8-OHdG antibody conjugates that produce color changes that are proportional to urine 8-OHdG and that are discernible on a smartphone camera photograph. Paper strip accuracy, precision, and stability studies were performed with 8-OHdG solutions of varying concentrations. Urine was collected from 97 patients with diabetes who were receiving DR screening examinations, including 7-field fundus photographs. DR was graded by standard methods as either low risk (no or mild DR) or high risk (moderate or severe DR). Paper sensor assays were performed on urine samples from patients and 8-OHdG values were correlated with DR grades. The differences in 8-OHdG values between the low- and high-risk groups were analyzed for outliers to identify the threshold 8-OHdG value that would minimize false-negative results.

Results

Lateral flow immunoassay paper strips quantitatively measure 8-OHdG and were found to be accurate, precise, and stable. Average urine 8-OHdG concentrations in study patients were 22 ± 10 ng/mg of creatinine in the low-risk group and 55 ± 11 ng/mg of creatinine in the high-risk group. Screening cutoff values of 8-OHdG >50 ng/mg of creatinine or urine creatinine >1.5 mg minimized screen failures, with 91% sensitivity and 81% specificity.

Conclusions

Urinary 8-OHdG is a useful biomarker to screen DR. Quantitative 8-OHdG detection with the lateral flow immunoassay paper sensor and smartphone camera demonstrates its potential in DR screening. NOTE: Publication of this article is sponsored by the American Ophthalmological Society.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2020  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 213

P. 306-319 - mai 2020 Retour au numéro
Article précédent Article précédent
  • A Nomenclature to Describe the Sequence of Visual Field Defects in Progressive Thyroid Eye Disease–Compressive Optic Neuropathy (An American Ophthalmological Society Thesis)
  • Suzanne K. Freitag, Thidarat Tanking
| Article suivant Article suivant
  • Presentation and Progression of Papilledema in Cerebral Venous Sinus Thrombosis
  • Katy C. Liu, M. Tariq Bhatti, John J. Chen, Aaron M. Fairbanks, Rod Foroozan, Collin M. McClelland, Michael S. Lee, Celine E. Satija, Courtney E. Francis, Michael T. Wildes, Prem S. Subramanian, Zoë R. Williams, Mays A. El-Dairi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.