Reprint requests: Zhuan Liao, National Clinical Research Center for Digestive Diseases, Department of Gastroenterology, Changhai Hospital, Naval Medical University, 168 Changhai Rd, Shanghai 200433, China.National Clinical Research Center for Digestive DiseasesDepartment of GastroenterologyChanghai HospitalNaval Medical University168 Changhai RdShanghai200433China

Abstract

Background and Aims

Compared with conventional endoscopy, magnetically controlled capsule gastroscopy (MCCG) can be further optimized in gastric examination time and complete visualization of upper GI (UGI) mucosa. The second-generation MCCG (MCCG-2) was developed with higher image resolution and adaptive frame rate, and we aimed to evaluate its clinical availability for UGI examination in this study.

Methods

Consecutive patients undergoing MCCG examination between May to June 2019 were prospectively enrolled and randomized to swallow the first-generation MCCG (MCCG-1) or MCCG-2 in a 1:1 ratio. The main outcomes included visualization of the esophagus and duodenum, operation-related parameters, image quality, maneuverability, detection of lesions, and safety evaluation.

Results

Eighty patients were enrolled. In the MCCG-2 group, frames captured for esophageal mucosa and Z-line were 171.00 and 2.00, significantly increased from those in the MCCG-1 group (97.00 [P = .002] and .00 [P = .028], respectively). The gastric examination time was shortened from 7.78 ± .97 minutes to 5.27 ± .74 minutes (P < .001), with the total running time of the capsule extended from 702.83 minutes to 1001.99 minutes (P < .001). MCCG-2 also greatly improved the image quality (P < .001) and maneuverability (P < .01). No statistical difference existed in the detection of lesions between the 2 groups, and no adverse events occurred.

Conclusions

MCCG-2 showed better performance in mucosal visualization, examination duration, and maneuverability, making better diagnosis of UGI diseases a possibility. (Clinical trial registration number: NCT 03977935.)

Le texte complet de cet article est disponible en PDF.

Abbreviations : CE, fps, GET, MCCG, UGI


Plan


 DISCLOSURE: The following authors received research support for this study from the Chang Jiang Scholars Program by the Chinese Ministry of Education (grant Q2015190) and the “Ten Thousand Plan” National High Level Talents Special Support Plan: Z. Liao; and Shanghai Sailing Program, China: Y.-Y. Qian (no. 19YF1446700), J. Pan (no. 18YF1422800). All other authors disclosed no financial relationships.
 If you would like to chat with an author of this article, you may contact Dr Liao at zhuanleo@126.com.


© 2020  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 91 - N° 6

P. 1379-1387 - juin 2020 Retour au numéro
Article précédent Article précédent
  • Continuing Medical Education Exam: June 2020
  • Karthik Ravi, William Ross, Ara Sahakian, Brian Weston, Prasad G. Iyer, Amit Rastogi, Michael B. Wallace
| Article suivant Article suivant
  • Endoscopic gastric body plication for the treatment of obesity: technical success and safety of a novel technique (with video)
  • Pichamol Jirapinyo, Christopher C. Thompson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.