International gestational age-specific centiles for umbilical artery Doppler indices: a longitudinal prospective cohort study of the INTERGROWTH-21st Project - 26/07/20

Doi : 10.1016/j.ajog.2020.01.012 
Lior Drukker, MD a, b, Eleonora Staines-Urias, PhD a, José Villar, MD a, b, Fernando C. Barros, MD d, e, Maria Carvalho, MD f, Shama Munim, FRCOG g, Rose McGready, MD c, h, Francois Nosten, MD c, h, James A. Berkley, FRCPCH c, i, Shane A. Norris, PhD j, Ricardo Uauy, MD k, l, Stephen H. Kennedy, MD a, b, Aris T. Papageorghiou, MD a, b,
a Nuffield Department of Women’s & Reproductive Health, University of Oxford, Oxford, United Kingdom 
b Oxford Maternal & Perinatal Health Institute, Green Templeton College, University of Oxford, Oxford, United Kingdom 
c Centre for Tropical Medicine and Global Health, University of Oxford, Oxford, United Kingdom 
d Programa de Pós-Graduação em Saúde e Comportamento, Universidade Católica de Pelotas, Pelotas, Brazil 
e Programa de Pós-Graduação em Epidemiologia, Universidade Federal de Pelotas, Pelotas, Brazil 
f Faculty of Health Sciences, Aga Khan University, Nairobi, Kenya 
g Department of Obstetrics and Gynecology, Aga Khan University Hospital, Karachi, Pakistan 
h Shoklo Malaria Research Unit, Mahidol-Oxford Tropical Medicine Research Unit, Faculty of Tropical Medicine, Mahidol University, Mae Sot, Thailand 
i KEMRI/Wellcome Trust Research Programme, Kilifi, Kenya 
j SAMRC Development Pathway for Health Research Unit, Department of Paediatrics and Child Health, University of Witwatersrand, Johannesburg, South Africa 
k Department of Nutrition and Public Health Interventions Research, London School of Hygiene and Tropical Medicine, London, United Kingdom 
l Division of Paediatrics, Pontifical Universidad de Chile, Santiago, Chile 

Corresponding author: Prof Aris T. Papageorghiou, MD.

Abstract

Background

Reference values for umbilical artery Doppler indices are used clinically to assess fetal well-being. However, many studies that have produced reference charts have important methodologic limitations, and these result in significant heterogeneity of reported reference ranges.

Objectives

To produce international gestational age-specific centiles for umbilical artery Doppler indices based on longitudinal data and the same rigorous methodology used in the original Fetal Growth Longitudinal Study of the INTERGROWTH-21st Project.

Study Design

In Phase II of the INTERGROWTH-21st Project (the INTERBIO-21st Study), we prospectively continued enrolling pregnant women according to the same protocol from 3 of the original populations in Pelotas (Brazil), Nairobi (Kenya), and Oxford (United Kingdom) that had participated in the Fetal Growth Longitudinal Study. Women with a singleton pregnancy were recruited at <14 weeks’ gestation, confirmed by ultrasound measurement of crown–rump length, and then underwent standardized ultrasound every 5±1 weeks until delivery. From 22 weeks of gestation umbilical artery indices (pulsatility index, resistance index, and systolic/diastolic ratio) were measured in a blinded fashion, using identical equipment and a rigorously standardized protocol. Newborn size at birth was assessed using the international INTERGROWTH-21st Standards, and infants had detailed assessment of growth, nutrition, morbidity, and motor development at 1 and 2 years of age. The appropriateness of pooling data from the 3 study sites was assessed using variance component analysis and standardized site differences. Umbilical artery indices were modeled as functions of the gestational age using an exponential, normal distribution with second-degree fractional polynomial smoothing; goodness of fit for the overall models was assessed.

Results

Of the women enrolled at the 3 sites, 1629 were eligible for this study; 431 (27%) met the entry criteria for the construction of normative centiles, similar to the proportion seen in the original fetal growth longitudinal study. They contributed a total of 1243 Doppler measures to the analysis; 74% had 3 measures or more. The healthy low-risk status of the population was confirmed by the low rates of preterm birth (4.9%) and preeclampsia (0.7%). There were no neonatal deaths and satisfactory growth, health, and motor development of the infants at 1 and 2 years of age were documented. Only a very small proportion (2.8%–6.5%) of the variance of Doppler indices was due to between-site differences; in addition, standardized site difference estimates were marginally outside this threshold in only 1 of 27 comparisons, and this supported the decision to pool data from the 3 study sites. All 3 Doppler indices decreased with advancing gestational age. The 3rd, 5th 10th, 50th, 90th, 95th, and 97th centiles according to gestational age for each of the 3 indices are provided, as well as equations to allow calculation of any value as a centile and z scores. The mean pulsatility index according to gestational age = 1.02944 + 77.7456*(gestational age)–2 – 0.000004455*gestational age3.

Conclusion

We present here international gestational age-specific normative centiles for umbilical artery Doppler indices produced by studying healthy, low-risk pregnant women living in environments with minimal constraints on fetal growth. The centiles complement the existing INTERGROWTH-21st Standards for assessment of fetal well-being.

Le texte complet de cet article est disponible en PDF.

Key words : antepartum testing, Doppler, fetal growth restriction, fetal well-being, INTERBIO, INTERGROWTH-21st ultrasound, longitudinal study, multinational study, perinatal morbidity, perinatal mortality, placenta, pulsatility index, reference ranges, resistance index, systolic/diastolic ratio, umbilical artery


Plan


 A.T.P. is a Senior Advisor of Intelligent Ultrasound.
 This project was supported by a generous grant from the Bill & Melinda Gates Foundation (grant no. 49038) to the University of Oxford, for which we are very grateful. A.T.P. is supported by the Oxford Partnership Comprehensive Biomedical Research Centre with funding from the NIHR Biomedical Research Centre (BRC) funding scheme. The funding sources had no involvement at any stage of research from design, conduct, to writing.
 Cite this article as: Drukker L, Staines-Urias E, Villar J, et al. International gestational age-specific centiles for umbilical artery Doppler indices: a longitudinal prospective cohort study of the INTERGROWTH-21st Project. Am J Obstet Gynecol 2020;222:602.e1-15.


© 2020  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 222 - N° 6

P. 602.e1-602.e15 - juin 2020 Retour au numéro
Article précédent Article précédent
  • Beyond the bladder: poor sleep in women with overactive bladder syndrome
  • Marissa B. Savoie, Kathryn A. Lee, Leslee L. Subak, Cesar Hernandez, Michael Schembri, Constance H. Fung, Deborah Grady, Alison J. Huang
| Article suivant Article suivant
  • Placental function and fetal weight are associated with maternal hemodynamic indices in uncomplicated pregnancies at 35–37 weeks of gestation
  • Coral Garcia-Gonzalez, Samira Abdel-Azim, Slavyana Galeva, Georgios Georgiopoulos, Kypros H. Nicolaides, Marietta Charakida

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.