S'abonner

Novel endoscopic technique for trisegment drainage in patients with unresectable hilar malignant biliary strictures (with video) - 21/08/20

Doi : 10.1016/j.gie.2020.03.003 
Yuta Maruki, MD 1, Susumu Hijioka, MD 1, ⁎, Shih Yea Sylvia Wu, MD 2, Akihiro Ohba, MD 1, Yoshikuni Nagashio, MD 1, Shunsuke Kondo, MD 1, Chigusa Morizane, MD 1, Hideki Ueno, MD 1, Takuji Okusaka, MD 1, Yutaka Saito, MD 2
1 Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, Tokyo, Japan 
2 Department of Endoscopy Division, National Cancer Center Hospital, Tokyo, Japan 

∗Reprint requests: Susumu Hijioka, MD, Department of Hepatobiliary and Pancreatic Oncology, National Cancer Center Hospital, 5-1-1 Tsukiji, Chuo-ku, Tokyo, Japan.Department of Hepatobiliary and Pancreatic OncologyNational Cancer Center Hospital5-1-1 TsukijiChuo-kuTokyoJapan

Abstract

Background and Aims

Three or more stents may be needed in patients with extensive stricturing in Bismuth type IIIa/IV hilar malignant strictures. Partial stent-in-stent (PSIS) deployment has been the primary intervention for hilar malignant biliary stricture (MBS). However, simultaneous side-by-side (SBS) stent placement has become feasible with the development of the <6F diameter stent delivery system. Our aim was to assess the efficacy and safety of a new hybrid method combining PSIS and SBS stent placement for trisegment biliary drainage.

Methods

This study included 17 consecutive patients with Bismuth IIIa or IV malignant strictures who underwent endoscopic drainage using the hybrid method. Diameters of the delivery stents were 5.4F (n = 10) and 5.7F (n = 7).

Results

The technical success rate was 82% (14/17), and the median length of procedures was 54 minutes. Two patients required predilatation for deployment of the third self-expandable metallic stent through the mesh of the first deployed stent. Two patients (12%) developed cholecystitis as early adverse events, and 1 patient (6%) developed liver abscess as a late adverse event. The time to recurrent biliary obstruction among those with successful initial trisegmental drainage was 189 days (95% confidence interval, 124-254).

Conclusions

The hybrid method for unresectable hilar MBS is an effective endoscopic drainage method, and the ease of these procedures is partly attributed to the thinner stent delivery system.

Le texte complet de cet article est disponible en PDF.

Abbreviations : MBS, PSIS, SBS, SEMS, TRBO


Plan


 DISCLOSURE: All authors disclosed no financial relationships. This work was supported in part by The National Cancer Center Research and Development Fund 31-A-13 and JFE (The Japanese Foundation for Research and Promotion of Endoscopy) Grant.
 If you would like to chat with an author of this article, you may contact Dr Hijioka at rizasusu@gmail.com.


© 2020  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 92 - N° 3

P. 763-769 - septembre 2020 Retour au numéro
Article précédent Article précédent
  • Surveillance for pathology associated with cancer on endoscopy (SPACE): criteria to identify high-risk gastric polyps in familial adenomatous polyposis
  • Gautam N. Mankaney, Michael Cruise, Shashank Sarvepalli, Amit Bhatt, Zubin Arora, Brian Baggot, Lisa Laguardia, Margaret O’Malley, James Church, Matthew Kalady, Carol A. Burke
| Article suivant Article suivant
  • The waterjet necrosectomy device for endoscopic management of pancreatic necrosis: design, development, and preclinical testing (with videos)
  • Patrick Yachimski, Claire A. Landewee, Federico Campisano, Pietro Valdastri, Keith L. Obstein

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.