S'abonner

Corneal Biomechanical Response Alteration After Scleral Buckling Surgery for Rhegmatogenous Retinal Detachment - 10/09/20

Doi : 10.1016/j.ajo.2020.03.054 
Leonardo Taroni a, ⁎ , Federico Bernabei a, Marco Pellegrini a, Matilde Roda a, Pier Giorgio Toschi a, Ashraf M. Mahmoud b, Costantino Schiavi a, Giuseppe Giannaccare a, c, Cynthia J. Roberts b
a Department of Ophthalmology, S.Orsola-Malpighi University Hospital, University of Bologna, Bologna, Italy 
b Department of Ophthalmology and Visual Science and Department of Biomedical Engineering, Ohio State University, Columbus, Ohio, USA 
c Department of Ophthalmology, University Magna Graecia of Catanzaro, Catanzaro, Italy 

∗Inquiries to Leonardo Taroni, Department of Ophthalmology, S.Orsola-Malpighi University Hospital, University of Bologna, Via Palagi 9, 40138 Bologna, ItalyDepartment of OphthalmologyS.Orsola-Malpighi University HospitalUniversity of BolognaVia Palagi 9Bologna40138Italy

Abstract

Purpose

To compare the corneal biomechanics of eyes that underwent scleral buckle (SB) for rhegmatogenous retinal detachment (RRD) with those of fellow eyes (fellow eyes) and to further investigate the effects of SB on intraocular pressure (IOP) values.

Design

Retrospective, fellow-eye matched cohort study.

Methods

A total of 18 consecutive patients (11 males and 7 females) treated with SB for RRD in 1 eye were enrolled. Goldmann applanation tonometry was used to measure IOP. Biomechanical properties of the cornea were investigated by using the Ocular Response Analyzer (ORA) (Reichert Instruments) for the calculation of corneal resistant factor (CRF), corneal hysteresis, Goldmann-correlated IOP, and corneal-compensated IOP. Customized software was used for analysis of the ORA infrared and pressure signals, and a significance threshold was set to a P value of .05.

Results

Operated eyes (OEs) showed significantly lower values of corneal hysteresis and CRF than fellow eyes (9.0 ± 1.8 vs 10.1 ± 1.8 mm Hg, respectively; P < .001; 10.0 ± 2.2 vs 10.9 ± 2.2 mm Hg; P < .001). GAT was significantly lower than corneal-compensated IOP in OEs (18.1 ± 4.9 vs 19.8 ± 4.8 mm Hg, respectively; P = .022) but not in fellow eyes. The second applanation event (A2) took place earlier in time, and the cornea was moving faster during A2 in the OEs than in the fellow eyes.

Conclusions

SB for the treatment of RRD affects corneal biomechanical response, likely due to a less compliant sclera that limits corneal motion and reduces energy dissipation, reflected in a lower corneal hysteresis. This has potentially meaningful clinical implications as the accuracy of the measurement of IOP values may be affected in these eyes.

Le texte complet de cet article est disponible en PDF.

Highlights

•
The encircling scleral buckle induces scleral stiffness, limiting corneal deformation.
•
Scleral buckling surgery affects the corneal biomechanical response.
•
A concave state of the cornea is more influenced by a less compliant sclera.
•
Routine IOP measurement accuracy may be affected in operated eyes.

Le texte complet de cet article est disponible en PDF.

Plan


© 2020  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 217

P. 49-54 - septembre 2020 Retour au numéro
Article précédent Article précédent
  • In Vivo Confocal Microscopy Morphologic Features and Cyst Density in Acanthamoeba Keratitis
  • Reena Chopra, Pádraig J. Mulholland, Scott C. Hau
| Article suivant Article suivant
  • Association Between 17-?-Estradiol and Interleukin-8 and Visual Field Progression in Postmenopausal Women with Primary Angle Closure Glaucoma
  • Shengjie Li, Haichen Zhang, Mingxi Shao, Yingzhu Li, Yunxiao Song, Xinghuai Sun, Wenjun Cao

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.