S'abonner

Basic morphological characteristics of coracoid grafts obtained by open and arthroscopic Latarjet techniques: A comparative study - 23/09/20

Doi : 10.1016/j.otsr.2020.04.014 
Alvaro Minuesa-Asensio a, Francisco García-Esteo b, José Ramón Mérida-Velasco c, Carmen Barrio-Asensio c, Crótida de la Cuadra-Blanco c, Jorge Murillo-González c,
a Head of Service of the Hospital Fraternidad-Muprespa, Madrid, Spain 
b Service of Traumatology, Jiménez Díaz Foundation, Madrid, Spain 
c Department of Anatomy and Embryology, Faculty of Medicine, Complutense University of Madrid, 28040 Madrid, Spain 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

A knowledge of the anthropometric characteristics of the coracoid graft (CG) that can be obtained by the open and arthroscopic Latarjet techniques may be beneficial in the preoperative planning and intraoperative decision making for coracoid osteotomy and transfer. We have not found any study that compared the morphology of the CG that can be obtained from open and arthroscopic Latarjet techniques. The purpose of this study was to verify if the basic anthropometric characteristics of CGs are equivalent.

Hypothesis

We hypothesize that the basic anthropometric characteristics of the CGs are similar.

Methods

Twenty fresh-frozen human paired cadaveric shoulder specimens that had been randomly distributed in two groups of 10 specimens each were used. Two surgeons, each with experience in performing the open and arthroscopic Latarjet technique, performed these procedures in each of the respective groups (OG, open group; AG, arthroscopic group). A CT scan was performed. Using the volume rendering technique, a metric analysis of the volume, area and length of the CG were performed, evaluated and statistically analysed.

Results

There were no significant differences in length (p=0.162) (mean length, 22.6mm for OG and 23.6mm for AG). There were significant differences in the volume (p=0.031) and area (p=0.007) of the CG, being lower in the OG (mean volume, 2.8 cm3 for OG and 3.6 cm3 for AG; mean area, 9.9 cm2 for OG and 12.8 cm2 for AG). No significant differences were observed by sex or laterality.

Conclusion

The mean lengths of the CGs that were obtained by each technique are equivalent. However, the areas and volumes of the grafts are different, being lower in the open surgery. These differences have not been an impediment to perform the technique. Our results corroborates that consolidation is more related to the preparation and placement than to the anthropometric characteristics of the CG. No significant differences were observed by sex or laterality.

Level of evidence

Basic Science.

Le texte complet de cet article est disponible en PDF.

Keywords : Shoulder, Instability, Open Latarjet, Arthroscopic, Technique, Coracoid graft, Morphologic characteristics


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 6

P. 1083-1087 - octobre 2020 Retour au numéro
Article précédent Article précédent
  • Isokinetic evaluation of the shoulder and elbow after Latarjet procedure
  • Eduardo A. Malavolta, Diego G. Cruz, Mauro Emilio Conforto Gracitelli, Jorge H. Assunção, Fernando B. Andrade-Silva, Felix R. Andrusaitis, Arnaldo A. Ferreira Neto
| Article suivant Article suivant
  • Mechanical behavior of screw versus Endobutton for coracoid bone-block fixation
  • Vadim Azoulay, Jérôme Briot, Pierre Mansat, Pascal Swider, Nicolas Bonnevialle

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.