S'abonner

Balloon Filling Algorithm for Optimal Size of Balloon Expandable Prosthesis During Transcatheter Aortic Valve Replacement - 13/10/20

Doi : 10.1016/j.amjcard.2020.07.058 
Gerhard Schymik, MD a, , Milos Radakovic, MD a, Peter Bramlage, MD b, Claus Schmitt, MD a, Panagiotis Tzamalis, MD a
a Medical Clinic IV – Department of Cardiology, Municipal Hospital Karlsruhe, Academic Teaching Hospital of the University of Freiburg, Germany 
b Institute for Pharmacology and Preventive Medicine, Cloppenburg, Germany 

Corresponding author. Tel.: +49 721 9742960; fax: +49 721 9742909.

Résumé

Aim is to report on the results of an optimized balloon filling algorithm and suggest a refinement of the implantation approach to maximize safety. Appropriate sizing of balloon expandable valves during transcatheter aortic valve implantation is crucial. Study comprised 370 consecutive patients receiving SAPIEN 3 valve between 2015 and 2018. Valve expansion/recoil measurement in the inflow area, annular area, and outflow area was performed previously and postimplantation. Nominal balloon filling resulted in underexpansion—23 mm (20.96 mm), 26 mm (23.88 mm), and 29 mm (27.56 mm) SAPIEN 3 valves at the annular level. Increased balloon filling by 2 cc resulted in a gradual increase in valve diameter reaching 97.35% (23 mm), 96.50% (26 mm), and 96.11% (29 mm) of the nominal valve diameter. Final diameters were usually higher in the valvular inflow and outflow tracts. The 29 mm valve did not reach its nominal diameter with 2 cc overfilling and in none of inflow area (95.48%), annular area (96.11%), or outflow area (96.86%). Device success (by VARC II) was 96.2%. No root or septal rupture, device migration, mitral valve injury, coronary obstruction, or dissection occurred. Rate of new permanent pacemaker implantation was 8.3%. Paravalvular leakage was none or trace in most patients. Mean valve gradient was 10.77 mm Hg postprocedure. 1.9% of the patients had a maximum gradient of >40 mm Hg, 2.2% >20 mm Hg. In conclusion, an optimized balloon filling algorithm resulted in appropriate valve gradients, low levels of paravalvular leakage, low rates of permanent pacemaker implantation and no annular rupture.

Le texte complet de cet article est disponible en PDF.

Plan


 This registry was conducted without any external financial support.


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 134

P. 108-115 - novembre 2020 Retour au numéro
Article précédent Article précédent
  • Effect of Progression of Valvular Calcification on Left Ventricular Structure and Frequency of Incident Heart Failure (from the Multiethnic Study of Atherosclerosis)
  • Oluwaseun E. Fashanu, Sireesha Upadhrasta, Di Zhao, Matthew J. Budoff, Ambarish Pandey, Joao A.C. Lima, Erin D. Michos
| Article suivant Article suivant
  • Comparison of the Usefulness of Strain Imaging by Echocardiography Versus Computed Tomography to Detect Right Ventricular Systolic Dysfunction in Patients With Significant Secondary Tricuspid Regurgitation
  • Kensuke Hirasawa, Philippe J. van Rosendael, Marlieke F. Dietz, Nina Ajmone Marsan, Victoria Delgado, Jeroen J Bax

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.