Abstract

Background

Precise implant alignment is a crucial prognostic factor for successful outcomes following total hip arthroplasty (THA). A portable accelerometer-based navigation (PN) device may achieve the same accuracy as that achieved by the computer-assisted navigation surgery technique, with the convenience of a conventional technique. Although the usefulness of PN in THA (PN-THA) has been reported, whether it is more accurate than performing THA with a conventional technique (CON-THA) remains controversial. The difference in surgical time between PN-THA and CON-THA is also unclear. Therefore, we conducted a systematic review and meta-analysis of studies comparing results of PN-THA with those of CON-THA. We focused on the following question: is PN-THA superior to CON-THA in terms of radiological parameters and surgical time?

Patients and Methods

A literature search was conducted in PubMed, Web of Science, and Cochrane Library, to identify studies that met the following inclusion criteria: randomised controlled trials (RCT) or non-RCT, studies involving patients who underwent PN-THA and patients who underwent CON-THA, studies including data on radiological parameters and surgical outcomes. Author names, publication year, country, study design, surgical approach, demographic characteristics of the participants (diagnosis, gender, age, and body mass index), and surgical outcomes (the radiological parameters and the surgical time) were extracted. We calculated the mean differences (MDs) for continuous data with 95% confidence intervals (CIs) for each outcome. p<0.05 was considered significant.

Results

Three studies were included in this meta-analysis. The meta-analysis showed that absolute deviation of the postoperative measured angles from the target position for the cup anteversion was significantly smaller in PN-THA than in CON-THA (MD=−1.70, 95% CI=−2.91 to −0.50, [p=0.005]). There was no significant difference in the absolute deviation of the postoperative measured angles from the target position for cup abduction between the groups (MD=−1.82, 95% CI=−4.32–0.67, [p=0.15]). The surgical time was significantly longer in PN-THA than in CON-THA (MD=8.58, 95% CI=4.05–13.10, [p=0.0002]).

Discussion

This systematic review and meta-analysis of studies comparing the results of PN-THA with those of CON-THA showed that the PN-THA is advantageous for precise cup implantation compared to CON-THA, although PN-THA has a longer surgical time compared to CON-THA.

Level of evidence

III.

Le texte complet de cet article est disponible en PDF.

Keywords : Total hip arthroplasty, Portable, Hand-held, Navigation, Systematic review, Meta-analysis

Abbreviations : PN, CON, MD, RCT, CAS


Plan


© 2020  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 107 - N° 1

Article 102742- février 2021 Retour au numéro
Article précédent Article précédent
  • Cementless hip revision cup for the primary fixation of osteoporotic acetabular fractures in geriatric patients
  • Christopher A. Becker, Christoph Linhart, Jan Bruder, Christian Zeckey, Axel Greiner, Adrian Cavalcanti Kußmaul, Simon Weidert, Eduardo M. Suero, Wolfgang Böcker, Christian Kammerlander
| Article suivant Article suivant
  • Symptomatic leg length discrepancy after total hip arthroplasty is associated with new onset of lower back pain
  • Felix W.A. Waibel, Kersten Berndt, Thorsten Jentzsch, Jan Farei-Campagna, Stefan Rahm, Claudio Dora, Patrick O. Zingg

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.