Aim

Pump thrombosis (PT) is a detrimental complication of left ventricular assist device (LVAD) therapy. There is no consensus on optimal PT treatment. The aim of this study was to present a treatment strategy for patients with PT.

Method

The hospital records of patients who underwent isolated LVAD implantation between May 2013 and October 2018 were retrospectively evaluated. Pump thrombosis was suspected in the setting of impaired flow/power parameters and haemolysis. Protocols for the management of suspected PT varied by patient presentation. Parameters that increased the PT risk were investigated by dividing the patients into two groups according to the presence of PT. Preoperative and operative data were analysed.

Results

Pump thrombosis was observed in 20 of 81 patients. All patients with PT presented elevated lactate dehydrogenase levels and higher power and/or low-/high-flow alarm at admission. All patients were treated initially with intravenous unfractionated heparin infusion; three patients did not require further treatment, one patient died due to sudden cardiac arrest, and three patients underwent urgent surgery for LVAD exchange. Thirteen (13) patients received tissue plasminogen activator infusion; eight were discharged without any signs of thrombosis, and three were bridged to transplant. One (1) major bleeding event leading to death was observed. Freedom from second PT was found in 91% cases at 6 months and in 68.2% at 1 year. We found that a larger left ventricle and the type of pump determined the risk of PT.

Conclusions

Low-dose thrombolytic therapy should be considered as a feasible treatment option for patients with PT.

Le texte complet de cet article est disponible en PDF.

Keywords : Continuous-flow, Left ventricular assist device, Pump thrombosis, Thrombolysis


Plan


© 2020  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 30 - N° 4

P. 567-576 - avril 2021 Retour au numéro
Article précédent Article précédent
  • Ventricular Tachycardia Storm Ablation With Pre-Emptive Circulatory Support by Extracorporeal Membrane Oxygenation: Australian Experience
  • Timothy Campbell, Richard G. Bennett, Vickie Lee, Samual Turnbull, Adam Eslick, Natalie Kruit, Anand Pudipeddi, Alfred Hing, Eddy Kizana, Stuart P. Thomas, Saurabh Kumar
| Article suivant Article suivant
  • Percutaneous Left Ventricular Assist Device Leads to Heart Rhythm Stabilisation in Cardiogenic Shock: Results from the Dresden Impella Registry
  • Johannes Mierke, Tobias Loehn, Georg Ende, Sabrina Jahn, Silvio Quick, Uwe Speiser, Stefanie Jellinghaus, Christian Pfluecke, Axel Linke, Karim Ibrahim

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.