Inquiries to Donny W. Suh, Department of Ophthalmology and Visual Sciences, Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, Nebraska 68198-5540, USADepartment of Ophthalmology and Visual SciencesTruhlsen Eye InstituteUniversity of Nebraska Medical CenterOmahaNebraska68198-5540USA

Abstract

Purpose

Abusive head trauma (AHT) is the leading cause of infant death and long-term morbidity from injury. The ocular consequences of AHT are controversial, and the pathophysiology of retinal research findings is still not clearly understood. It has been postulated that vitreoretinal traction plays a major role in the retinal findings. A computer simulation model was developed to evaluate the vitreoretinal traction and determine whether the distribution of forces in different layers and locations of the retina can explain the patterns of retinal hemorrhage (RH) seen in AHT.

Design

Computer simulation model study.

Methods

A computer simulation model of the pediatric eye was developed to evaluate preretinal, intraretinal, and subretinal stresses during repetitive shaking. This model was also used to examine the forces applied to various segments along blood vessels.

Results

Calculated stress values from the computer simulation ranged from 3-16 kPa at the vitreoretinal interface through a cycle of shaking. Maximal stress was observed at the periphery of the retina, corresponding to areas of multiple vessel bifurcations, followed by the posterior pole of the retina. Stress values were similar throughout all 3 layers of the retina (preretinal, intraretinal, and subretinal layers).

Conclusions

Ocular manifestations from AHT revealed unique retinal characteristics. The model predicted stress patterns consistent with the diffuse retinal hemorrhages (RH) typically found in the posterior pole and around the peripheral retina in AHT. This computer model demonstrated that similar stress forces were produced in different layers of the retina, consistent with the finding that retinal hemorrhages are often found in multiple layers of the retina. These data can help explain the RH patterns commonly found in AHT.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at A.J.O.com.


© 2020  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 223

P. 396-404 - mars 2021 Retour au numéro
Article précédent Article précédent
  • Remission of Non-Infectious Anterior Scleritis: Incidence and Predictive Factors
  • John H. Kempen, Maxwell Pistilli, Hosne Begum, Tonetta D. Fitzgerald, Teresa L. Liesegang, Abhishek Payal, Nazlee Zebardast, Nirali P. Bhatt, C. Stephen Foster, Douglas A. Jabs, Grace A. Levy-Clarke, Robert B. Nussenblatt, James T. Rosenbaum, H. Nida Sen, Eric B. Suhler, Jennifer E. Thorne, Systemic Immunosuppressive Therapy for Eye Diseases (SITE) Cohort Study Research Group
| Article suivant Article suivant
  • Analysis of Predisposing Clinical Features for Worsening Traction After Treatment of Familial Exudative Vitreoretinopathy in Children
  • G. Baker Hubbard, Alexa L. Li

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.