S'abonner

New technique to evaluate decontamination methods for filtering facepiece respirators - 24/03/21

Doi : 10.1016/j.ajic.2021.01.017 
Evanly Vo, PhD, DDS a, , Samy Rengasamy, PhD a, Susan Xu, PhD a, Matthew Horvatin, BS b, Ziqing Zhuang, PhD a
a National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA 
b Amentum, Aiken, SC 

Address correspondence to Evanly Vo, PhD, DDS, National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, 626 Cochrans Mill Rd, Pittsburgh, PA 15236.National Institute for Occupational Safety and HealthNational Personal Protective Technology Laboratory626 Cochrans Mill RdPittsburghPA15236

Highlights

Both ultraviolet germicidal irradiation and moist heat decontamination methods did not degrade the respirator performance.
The ultraviolet germicidal irradiation and moist heat methods inactivated MS2 virus (>5-log reduction) consistently.
UV decon efficacy order: aerosol-based >vapor-based >solution-based deposition.
Generally, decontamination efficacy order: hydrophilic filtering facepiece respirator slightly >hydrophobic filtering facepiece respirator.
All 3 varying virus loading types could be repeatably and reproducibly achieved.

Le texte complet de cet article est disponible en PDF.

ABSTRACT

Background

A major concern among health care experts is a shortage of N95 filtering facepiece respirators (FFRs) during a pandemic. One option for mitigating an FFR shortage is to decontaminate and reuse the devices. The focus of this study was to develop a new evaluation technique based on 3 major decontamination requirements: (1) inactivating viruses, (2) not altering the respirator properties, and (3) not leaving any toxic byproduct on the FFR.

Methods

Hydrophilic and hydrophobic FFRs were contaminated with MS2 virus. In the solution-based deposition, the virus-containing liquid droplets were spiked directly onto FFRs, while in the vapor-based and aerosol-based depositions, the viral particles were loaded onto FFRs using a bio-aerosol testing system. Ultraviolet germicidal irradiation (UVGI) and moist heat (MH) decontamination methods were used for inactivation of viruses applied to FFRs.

Results

Both UVGI and MH methods inactivated viruses (>5-log reduction of MS2 virus; in 92% of both method experiments, the virus was reduced to levels below the detection limit), did not alter the respirator properties, and did not leave any toxic byproduct on the FFRs.

Conclusions

Both UVGI and MH methods could be considered as promising decontamination candidates for inactivation of viruses for respirator reuse during shortages.

Le texte complet de cet article est disponible en PDF.

Key Words : N95 respirator, MS2 virus, Disinfection, UVGI, Moist heat, Infection control


Plan


 Conflicts of interest: None to report.


© 2021  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 49 - N° 4

P. 416-423 - avril 2021 Retour au numéro
Article précédent Article précédent
  • A laboratory model demonstrating the protective effects of surgical masks, face shields, and a combination of both in a speaking simulation
  • Hossein Salimnia, Monica P. Meyer, Robert Mitchell, Marilynn R. Fairfax, Angela Gundel, Navneet Guru, Teena Chopra
| Article suivant Article suivant
  • UV-C tower for point-of-care decontamination of filtering facepiece respirators
  • Badar J. Kayani, Davis T. Weaver, Vishhvaan Gopalakrishnan, Eshan S. King, Emily Dolson, Nikhil Krishnan, Julia Pelesko, Michael J. Scott, Masahiro Hitomi, Jennifer L. Cadnum, Daniel F. Li, Curtis J. Donskey, Jacob G. Scott, Ian Charnas

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.