S'abonner

Total motorized spiral enteroscopy: first prospective clinical feasibility trial - 13/05/21

Doi : 10.1016/j.gie.2020.10.028 
Torsten Beyna, MD 1, , Marianna Arvanitakis, MD, PhD 2, Markus Schneider, MD 1, Christian Gerges, MD 1, Joerg Hoellerich, MD 1, Jacques Devière, MD, PhD 2, Horst Neuhaus, MD, PhD 1
1 Department of Internal Medicine and Gastroenterology, Evangelisches Krankenhaus Düsseldorf, Düsseldorf, Germany 
2 Department of Gastroenterology and Hepato-Pancreatology, Erasme Hospital, Université Libre des Bruxelles, Brussels, Belgium 

Reprint requests: Torsten Beyna, MD, Evangelisches Krankenhaus Düsseldorf, Department of Internal Medicine and Gastroenterology, Kirchfeldstr 40, 40217 Düsseldorf, Germany.Evangelisches Krankenhaus DüsseldorfDepartment of Internal Medicine and GastroenterologyKirchfeldstr 40Düsseldorf40217Germany

Abstract

Background and Aims

Motorized spiral enteroscopy (MSE) was recently introduced into clinical practice and shown to be safe and effective for antegrade enteroscopy. The aim of the current trial was to prospectively study the efficacy and safety of MSE for visualization of the entire small bowel.

Methods

All consecutive patients with indications for complete enteroscopy meeting the inclusion criteria were enrolled in a prospective observational bicentric trial, starting with antegrade MSE; a retrograde approach was performed if MSE remained incomplete from antegrade. The primary objective was to ascertain the total enteroscopy rate (TER); secondary objectives were diagnostic yield, procedural success, time, depth of maximum insertion (DMI), therapeutic yield, and adverse events (AEs).

Results

Thirty patients (16 women, 14 men; median age 64 years [range, 37-100]) were enrolled. Technical success rate of antegrade MSE (advancement beyond the ligament of Treitz) and retrograde MSE (advancement beyond the ileocecal valve [ICV]) were 100% and 100%, respectively. Overall TER was 70%: 16.6% antegrade approach alone and 53.4% bidirectional approach. Median antegrade DMI distal from the ligament of Treitz was 490 cm (range, 160-600); median insertion time 26 minutes (range, 15-110). The median retrograde DMI beyond the ICV was 120 cm (range, 40-600), and median insertion time was 17 minutes (range, 1-68). Overall diagnostic and therapeutic yields were 80% and 86.7%, respectively. Overall AE rate was 16.7%. No serious AEs occurred.

Conclusions

This prospective study showed that complete enteroscopy is feasible with MSE, either from antegrade alone or bidirectionally, with high success rates and short procedural duration. These results justify further evaluation of MSE in a large prospective multicenter study, preferably with inclusion of a control group. (Clinical trial registration number: NCT03438695.)

Le texte complet de cet article est disponible en PDF.

Abbreviations : AE, DAE, DBE, DMI, ICV, MSE, PSE, SBE, SE, TER, TSR


Plan


 DISCLOSURE: The following authors disclosed financial relationships: T. Beyna, M. Arvanitakis, J. Devière, and H. Neuhaus: Consultant and speaker for Olympus Medical Systems Corporation. All other authors disclosed no financial relationships.


© 2021  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 93 - N° 6

P. 1362-1370 - juin 2021 Retour au numéro
Article précédent Article précédent
  • Do the 2019 ASGE choledocholithiasis guidelines reduce diagnostic ERCP?
  • Christopher Ko, James Buxbaum
| Article suivant Article suivant
  • Rev up your engines: a new approach to access the deep small bowel by motorized spiral enteroscopy
  • Usman Barlass, Joshua Melson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.