⁎Inquiries to Gerd U. Auffarth, Department of Ophthalmology, University of Heidelberg, Im Neuenheimer Feld 400, 69120 Heidelberg, Germany.Department of OphthalmologyUniversity of HeidelbergIm Neuenheimer Feld 400Heidelberg69120Germany

Highlights

•
High-resolution optical coherence tomography visualized intraocular lens (IOL) opacities.
•
The amount of IOL opacification correlated with the amount of induced straylight.
•
Linear regression estimated the impact of IOL opacities on the visual quality.

Le texte complet de cet article est disponible en PDF.

Résumé

Purpose

To quantify in vitro straylight induced by intraocular lens (IOL) localized opacification using an anterior segment optical coherence tomography (OCT) device.

Design

Laboratory investigation.

Methods

We obtained high-resolution OCT cross-section images of 44 explanted IOLs using a new in vitro application for an anterior segment OCT device, the Anterion (Heidelberg Engineering, Heidelberg, Germany). In 24 cases, the reason for IOL explantation was a centrally localized opacification, the sequela of a secondary ocular surgery. As a control, we used 20 IOLs removed after an IOL (sub-)luxation. Using image analysis, we found a threshold area value representing a metric for the amount of opacification in a region of interest in the IOL's central optic. We used a modified C-Quant straylight meter (Oculus, Wetzlar, Germany) to quantify light scattering. We derived a linear regression from calculating the correlation between the amount of opacification and straylight.

Results

We visualized different amounts of IOL opacification using the OCT device. The opacified lenses showed a mean threshold area of 6.7% ± 3.3% and mean straylight was 95.1 ± 75.6 deg2/sr. The clear group's mean threshold area was 2.0% ± 0.8% and 5.0 ± 3.4 deg2/sr mean straylight. Straylight correlated statistically significantly with the threshold area, with a correlation coefficient of R2 = 0.80, P < .001.

Conclusions

This high-resolution OCT imaging technique can be used to visualize IOL opacities. The amount of opacification correlated well with the straylight induced by the lens. Anterior segment OCT imaging might be used in the future as a tool for predicting the extent of visual impairment and aid clinicians to quantify patients' complaints.

Le texte complet de cet article est disponible en PDF.

Keywords : IOL calcification, intraocular lens opacity, biomaterial, IOL pathology, DMEK, Descemet Membrane Endothelial Keratoplasty, light scattering, glare


Plan


 Supplemental Material available at AJO.com.


© 2021  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 226

P. 108-116 - juin 2021 Retour au numéro
Article précédent Article précédent
  • Glaucoma Expert-Level Detection of Angle Closure in Goniophotographs With Convolutional Neural Networks: The Chinese American Eye Study
  • Michael Chiang, Daniel Guth, Anmol A. Pardeshi, Jasmeen Randhawa, Alice Shen, Meghan Shan, Justin Dredge, Annie Nguyen, Kimberly Gokoffski, Brandon J. Wong, Brian Song, Shan Lin, Rohit Varma, Benjamin Y. Xu
| Article suivant Article suivant
  • Effect of the EVO+ Visian Phakic Implantable Collamer Lens on Visual Performance and Quality of Vision and Life
  • Elena Martínez-Plaza, Alberto López-Miguel, Alberto López-de la Rosa, Colm McAlinden, Itziar Fernández, Miguel J. Maldonado

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.