Hydrogel-coated needles prevent puncture site bleeding in arteriovenous fistula and arteriovenous grafts in rats - 09/10/21

Doi : 10.1016/j.biopha.2021.112113 
Yanhua Xu a, c, 1, Zhiju Wang c, e, 1, Shunbo Wei b, c, 1, Peng Sun b, c, Hualong Bai b, c, , Jing’an Li d,
a Department of Internal Medicine, First Affiliated Hospital of Zhengzhou University, Henan, China 
b Department of Vascular and Endovascular Surgery, First Affiliated Hospital of Zhengzhou University, Henan, China 
c Key Vascular Physiology and Applied Research Laboratory of Zhengzhou City, Henan, China 
d School of Material Science and Engineering & Henan Key Laboratory of Advanced Magnesium Alloy & Key Laboratory of Materials Processing and Mold Technology (Ministry of Education), Zhengzhou University, Henan, China 
e Department of Physiology, Medical school of Zhengzhou University, Henan, China 

Correspondence to: Department of Vascular and Endovascular Surgery, First Affiliated Hospital of Zhengzhou University, Henan 450052, China.Department of Vascular and Endovascular Surgery, First Affiliated Hospital of Zhengzhou UniversityHenan450052China⁎⁎Correspondence to: School of Material Science and Engineering, Zhengzhou University, Henan 450001, China.School of Material Science and Engineering, Zhengzhou UniversityHenan450001China

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 5
Iconographies 5
Vidéos 0
Autres 0

Abstract

Introduction

Imperfect hemostasis after arteriovenous fistula (AVF) and arteriovenous graft (AVG) cannulation can cause a hematoma or pseudoaneurysm and leads to poor satisfaction. We hypothesized that a hydrogel-coated needle would effectively and rapidly stop bleeding after vascular cannulation in a rat AVF and AVG model.

Method

A hydrogel comprised of sodium alginate (SA), hyaluronic acid (HA), and calcium carbonate was coated onto the surface of suture needles using a rotating system. The needles were observed using scanning electron microscopy (SEM) and immunofluorescence. Rat AVF with or without renal failure and AVG were punctured using bare and hydrogel-coated needles. The tissues were examined by histology.

Result

The hydrogel was successfully coated onto the surface of 30 G needles and confirmed by SEM. Hydrogel-coated needles rapidly stopped bleeding after AVF and AVG cannulation in rat.

Conclusion

In this preliminary animal research, hydrogel-coated needles can stop AVF and AVG puncture-site bleeding; but additional clinical studies are needed to justify whether it is still effective in clinical.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




ga1

Le texte complet de cet article est disponible en PDF.

Highlights

Hydrogel-coated needles stopped the AVF and AVG puncture-site bleeding in rat.
A new arteriovenous graft model was established in rat.
The coating process can be easily achieved by a self-made rotating system.

Le texte complet de cet article est disponible en PDF.

Keywords : Hemostasis, Hydrogel, Needle, Arteriovenous fistula, Arteriovenous graft, Puncture, Cannulation


Plan


© 2021  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 143

Article 112113- novembre 2021 Retour au numéro
Article précédent Article précédent
  • Lycium barbarum polysaccharide attenuates emotional injury of offspring elicited by prenatal chronic stress in rats via regulation of gut microbiota
  • Feng Zhao, Suzhen Guan, Youjuan Fu, Kai Wang, Zhihong Liu, Tzi Bun Ng
| Article suivant Article suivant
  • Curcumin analogue C66 attenuates obesity-induced myocardial injury by inhibiting JNK-mediated inflammation
  • Lin Ye, Xiaojun Chen, Minxiu Wang, Leiming Jin, Zaishou Zhuang, Daona Yang, Xinfu Guan, Aleksandr V. Samorodov, Valentin N. Pavlov, Nipon Chattipakorn, Jianpeng Feng, Yi Wang, Wu Luo, Guang Liang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.