Patellar height is not modified after isolated open-wedge high tibial osteotomy without change in posterior tibial slope - 29/10/21

Doi : 10.1016/j.otsr.2021.103032 
Mathieu Carissimi a, b, Pierre Sautet a, b, Dimitri Charre a, Lukas Hanak c, Matthieu Ollivier a, b, Grégoire Micicoi d, e,
a Department of Orthopedics and Traumatology, Institute of Movement and Locomotion, Sainte-Marguerite Hospital, 270, boulevard Sainte-Marguerite, BP 29, 13274 Marseille, France 
b Department of Orthopedics and Traumatology, CNRS, ISM, Sainte-Marguerite Hospital, Aix Marseille University, AP–HM, Institute for Locomotion, Marseille, France 
c Orthopädie Maximilium, Donauwörth, Germany 
d UR2CA, université Côte d’Azur, 06000 Nice, France 
e iULS-University Institute for Locomotion and Sports, Pasteur 2 Hospital, University Côte d’Azur, Nice, France 

*Corresponding author at:iULS-University Institute for Locomotion and Sports, Pasteur 2 Hospital, University Côte d’Azur, Nice, France.iULS-University Institute for Locomotion and Sports, Pasteur 2 Hospital, University Côte d’AzurNiceFrance

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

Open-wedge high tibial osteotomy (OWHTO) corrects coronal deformity and can impact sagittal parameters such as posterior tibial slope and patellar height. The aim of the present study was to analyze change in patellar height after medial OWHTO with respect to tibial and femoral-referenced indices.

Material and method

This single-center retrospective study included 129 patients undergoing isolated posteromedial OWHTO, without change in tibial slope, using patient-specific cutting-guides. Patellar height was assessed on Caton-Deschamps (CD), Insall-Salvati (IS) and Schröter indices. Posterior tibial slope and coronal femoral and tibial angles were also measured. X-rays were taken preoperatively and at 12 months, and analyzed by 2 independent observers.

Results

OWHTO modified the global lower-limb alignment (Δ=6.3±0.95̊, p<0.0001) and the proximal tibial deformity (Δ=7±0.88̊, p<0.0001). Posterior tibial slope and tibial (CD and IS) and femoral (Schröter) patellar height indices were unchanged. Intra- and inter-observer reproducibility was excellent (ICC 0.79–0.91). There were no correlations between HKA or MPTA angles and change in patellar height.

Conclusion

The present clinical series showed that patellar height was unchanged by isolated posteromedial OWHTO without change in tibial slope, using patient-specific cutting-guides, with whichever femoral or tibial reference index. The Schröter patellar femoral height index was highly reliable and is independent of proximal tibial changes in assessing patellar height, and can thus be recommended in the follow-up of OWHTO.

Level of evidence

III; retrospective cohort study.

Le texte complet de cet article est disponible en PDF.

Keywords : Patellar height, Open-wedge high tibial osteotomy, Posterior tibial slope, Deformity, Knee


Plan


© 2021  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 107 - N° 7

Article 103032- novembre 2021 Retour au numéro
Article précédent Article précédent
  • Prevalence of trochlear dysplasia in symptomatic isolated lateral patellofemoral osteoarthritis: Transverse study of 101 cases
  • Tristan De Leissègues, Stanislas Gunst, Cécile Batailler, Gunjan Kolhe, Sébastien Lustig, Elvire Servien
| Article suivant Article suivant
  • Flexion contracture can be relieved by concurrent notchplasty in medial open wedge high tibial osteotomy
  • Ju-Ho Song, Seong-Il Bin, Jong-Min Kim, Bum-Sik Lee, Jung-Su Choe, Hyung-Kwon Cho

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.