Nifedipine disturbs fetal cardiac function during hypoxemia in a chronic sheep model at near term gestation - 29/10/21

Abstract |
Background |
Nifedipine is a widely used drug in pregnancies complicated by maternal hypertensive disorders that can be associated with placental insufficiency and fetal hypoxemia. The evidence regarding fetal myocardial responses to nifedipine in hypoxemia is limited.
Objective |
We hypothesized that nifedipine would not impair fetal sheep cardiac function under hypoxemic environment. In particular, we investigated the effects of nifedipine on fetal ventricular functional parameters and cardiac output.
Study Design |
A total of 21 chronically instrumented fetal sheep at 122 to 134 gestational days (term, 145 days) were included in this study. Fetal cardiac function was evaluated by measuring global longitudinal strain, indices describing ventricular systolic and diastolic function, and cardiac outputs using two-dimensional speckle tracking and tissue and spectral pulsed-wave Doppler echocardiography. Fetal carotid artery blood pressure and blood gas values were invasively monitored. After baseline data collection, fetal hypoxemia was induced by maternal hyperoxygenation. After hypoxemia phase data collection, 9 fetuses received nifedipine infusion, and 12 fetuses received saline infusion. Data were collected 30 and 120 minutes after the infusion was started. After 120 minutes of data collection, maternal and fetal oxygenation were normalized, and normoxemia phase data were collected, while infusion was continued.
Results |
Hypoxemia decreased fetal carotid artery mean arterial pressure from 40 (8) mm Hg to 35 (8) mm Hg (P<.007), and left ventricular global longitudinal strain showed less deformation than at baseline (P=.001). Under hypoxemia, nifedipine caused a reduction in right ventricular global longitudinal strain (P<.05), a decrease in right ventricular isovolumic relaxation velocity and its deceleration (P<.01) indicating diastolic dysfunction, and a drop in right ventricular cardiac output (P<.05). Nifedipine did not alter fetal left ventricular functional parameters or cardiac output. When normoxemia was restored, fetal right ventricular functional parameters and cardiac output returned to baseline level.
Conclusion |
In hypoxemic fetus, nifedipine impaired right ventricular function and reduced its cardiac output. The detrimental effects of nifedipine on fetal right ventricular function were abolished, when normoxemia was restored. Our findings suggest that in a hypoxemic environment nifedipine triggers detrimental effects on fetal right ventricular function.
Le texte complet de cet article est disponible en PDF.Key words : antihypertensive medication, blood flow, heart, hemodynamics, hypertension, physiology, pregnancy, ultrasound
Plan
| G.A. and J.R. contributed equally to this work. |
|
| The authors report no conflict of interest. |
|
| This research was funded, in part, by a grant from the Regional Health Authority of Northern Norway and, in part, by a salary from the University of Eastern Finland. |
|
| Cite this article as: Alanne L, Bhide A, Lantto J, et al. Nifedipine disturbs fetal cardiac function during hypoxemia in a chronic sheep model at near term gestation. Am J Obstet Gynecol 2021;225:544.e1-9. |
Vol 225 - N° 5
P. 544.e1-544.e9 - novembre 2021 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?
