S'abonner

Viability of Performing Multiple 24-2 Visual Field Examinations at the Same Clinical Visit: The Frontloading Fields Study (FFS) - 13/11/21

Doi : 10.1016/j.ajo.2021.04.019 
Jack Phu 1, 2, , Michael Kalloniatis 1, 2
1 Centre for Eye Health, University of New South Wales, Kensington, NSW 
2 School of Optometry and Vision Science, University of New South Wales, Kensington, NSW, Australia 

Inquiries to Jack Phu, Centre for Eye Health, Gate 14 Barker Street Rupert Myers Building South Wing, University of New South Wales, Sydney 2052, New South Wales, Australia.Centre for Eye HealthUniversity of New South Wales, SydneyGate 14 Barker Street Rupert Myers Building South WingNew South Wales2052Australia

HIGHLIGHTS

Frontloading SITA-Faster tests yield repeatable and reliable results.
Four visual field test results can be obtained in less than 20 minutes.
These results can facilitate adherence to recommendations on frequency of perimetric testing.

Le texte complet de cet article est disponible en PDF.

Résumé

Purpose

To assess the viability, in terms of time taken for testing and repeatability, of frontloading (performing multiple perimetric examinations) in a single clinic visit.

Design

Reliability enhancement analysis.

Methods

A total of 329 healthy glaucoma suspect and glaucoma subjects within a glaucoma clinic undergoing perimetric testing using SITA-Faster twice for each eye within the same session were included. Global indices, pointwise sensitivity and probability scores, test duration, and reliability metrics were analysed.

Results

For both tests 9.1% of right eye and 6.7% of left eye results were unreliable, with 58.4% and 67.5% of right and left eyes achieving reliable results, respectively; 83.8% of all subjects spent less than 20 minutes performing all tests. Differences in global indices, pointwise sensitivity and probability scores showed no systematic or clinically significant difference between tests one and two for each eye. There was also no systematic difference in the number of test locations identified as defective at the P < .05 level between tests. Test results that were unreliable tended to show more instances of a failed “cluster” criterion that were not repeatable.

Conclusions

Frontloading using SITA-Faster was viable for obtaining sets of reliable, repeatable perimetric data in terms of conventional outputs, overcoming practical issues regarding low test reliability using singleton results and confirmation of visual field defects. Despite the need to remain cognisant of the reliability of SITA-Faster, frontloading using this algorithm may be a practical method for meeting recommendations for multiple perimetric data required to make confident inferences about glaucoma state and progression.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2021  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 230

P. 48-59 - octobre 2021 Retour au numéro
Article précédent Article précédent
  • KCNV2-Associated Retinopathy: Detailed Retinal Phenotype and Structural Endpoints—KCNV2 Study Group Report 2
  • Michalis Georgiou, Kaoru Fujinami, Ajoy Vincent, Fadi Nasser, Samer Khateb, Mauricio E. Vargas, Alberta A.H.J. Thiadens, Emanuel R. de Carvalho, Xuan-Thanh-An Nguyen, Thales Antônio Cabral De Guimarães, Anthony G. Robson, Omar A. Mahroo, Nikolas Pontikos, Gavin Arno, Yu Fujinami-Yokokawa, Shaun Michael Leo, Xiao Liu, Kazushige Tsunoda, Takaaki Hayashi, Belen Jimenez-Rolando, Maria Inmaculada Martin-Merida, Almudena Avila-Fernandez, Ester Carreño, Blanca Garcia-Sandoval, Carmen Ayuso, Dror Sharon, Susanne Kohl, Rachel M. Huckfeldt, Camiel J.F. Boon, Eyal Banin, Mark E. Pennesi, Bernd Wissinger, Andrew R. Webster, Elise Héon, Arif O. Khan, Eberhart Zrenner, Michel Michaelides
| Article suivant Article suivant
  • Clinically Relevant Activity of the Novel RASP Inhibitor Reproxalap in Allergic Conjunctivitis: The Phase 3 ALLEVIATE Trial
  • David Clark, Bill Cavanagh, Alan L. Shields, Paul Karpecki, John Sheppard, Todd C. Brady

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.