Discriminating between IgG4-related orbital disease and other causes of orbital inflammation with intra voxel incoherent motion (IVIM) MR imaging at 3T - 08/12/21

Doi : 10.1016/j.diii.2021.06.006 
Natalia Shor a, b, , Thomas Sené c, Kevin Zuber d, Mathieu Zmuda e, Olivier Bergès a, Julien Savatovsky a, Augustin Lecler a
a Department of Neuroradiology, Fondation Adolphe de Rothschild Hospital, 75019 Paris, France 
b Department of Neuroradiology, Pitié-Salpêtriére Hospital, Assistance Publique-Hopitaux de Paris, 75013 Paris, France 
c Department of Internal Medicine, Fondation Adolphe de Rothschild Hospital, 75019 Paris, France 
d Department of Clinical Research, Fondation Adolphe de Rothschild Hospital, 75019 Paris, France 
e Department of Orbitopalpebral Surgery, Fondation Adolphe de Rothschild Hospital, 75019 Paris, France 

Corresponding author at: Department of Neuroradiology, Fondation Adolphe de Rothschild Hospital, 75019 Paris, France.Department of NeuroradiologyFondation Adolphe de Rothschild HospitalParis75019France

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

Structural MR imaging, including diffusion-weighted imaging does not allow distinguishing between IgG4-related ophthalmic disease (IgG4-ROD) and other types of orbital inflammation.
True diffusion coefficient (D) is greater in IgG4-ROD (median, 1 × 10-3 mm2/s; IQR: 0.9 × 10-3 –1.2 × 10-3) than in non IgG4-ROD (median, 0.80 × 10-3 mm2/s; IQR: 0.7 × 10-3–1 × 10-3) (P = 0.04).
The optimal threshold for true diffusion coefficient (D) to differentiate IgG4-ROD from non IgG4-ROD is 0.87 × 10-3 mm2/s, yielding 92% sensitivity (95% CI: 62–100%) and 71% specificity (95% CI: 44–90%).

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

The purpose of this prospective study was to determine the capabilities of intravoxel incoherent motion (IVIM) MRI at 3 Tesla in discriminating between IgG4-related orbital disease (IgG4-ROD) and other causes of orbital inflammation.

Materials and methods

Main selection criteria for the patients enrolled in this prospective study were age over 18 years and histopathologicaly proven orbital inflammatory lesion. MRI examinations were performed prior to surgery and treatment in all patients with suspected orbital inflammation. Two neuroradiologists, blinded to clinical data, independently analyzed structural MRI examinations and IVIM sequences obtained with 15 b values ranging from 0 to 2000 s/mm². Apparent diffusion coefficient (ADC), “true” diffusion coefficient (D), perfusion fraction (f) and pseudodiffusion coefficient (D*) values were calculated from all orbital lesions. Diagnostic capabilities of IVIM parameters were assessed using receiver operating-characteristic (ROC) curves and area under the curve (AUC). Sensitivity, specificity, and accuracy of IVIM parameters were calculated for the best threshold values and reported with their corresponding 95% confidence intervals (CI).

Results

Thirty-five patients (21 women and 14 men; mean age, 49.2 ± 13.75 [SD] years; age range: 23–77 years) with 48 orbital lesions were enrolled in the study. Fifteen patients (15/35; 43%) had IgG4-ROD and 20 (20/35; 57%) had other causes of orbital inflammation. Median D value was significantly greater in patients with IgG4-ROD (1 × 10-3 mm2/s; interquartile range [IQR]: 0.9 × 10-3; 1.2 × 10-3) as compared to patients with non IgG4-ROD (0.80 × 10-3 mm2/s; IQR: 0.7 × 10-3; 1 × 10-3) (P = 0.04). There was no significant difference for ADC, f or D*. Area under the curve were of 0.54, 0.73, 0.63 and 0.56 for ADC, D, f and D*, respectively. Optimal threshold derived from ROC curves for D was 0.87 × 10-3 mm2/s, yielding 92% sensitivity (95% CI: 62–100%) and 71% specificity (95% CI: 44–90%) for the diagnosis of IgG4-ROD. No differences in standard morphological MRI criteria were found between IgG4-ROD and non IgG4-ROD.

Conclusion

Our study shows that IVIM MRI is a useful imaging technique to distinguish IgG4-ROD from other causes of orbital inflammation.

Le texte complet de cet article est disponible en PDF.

Keywords : Diffusion magnetic resonance imaging, Immunoglobulin G4, Inflammation, Prospective studies, Magnetic resonance imaging (MRI)

Abbreviations : ADC, AUC, CI, D, DWI, D*, ICC, IgG4-ROD, IVIM, IQR, f, LoA, MRI, ROI, SD, WI


Plan


© 2021  Société française de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 102 - N° 12

P. 727-734 - décembre 2021 Retour au numéro
Article précédent Article précédent
  • Association between coronary artery calcifications and 6-month mortality in hospitalized patients with COVID-19
  • Elie Mousseaux, Antoine Fayol, Nicolas Danchin, Gilles Soulat, Etienne Charpentier, Marine Livrozet, Jean-Baptiste Carves, Victoria Tea, Fares Ben Salem, Chekrallah Chamandi, Jean-Sébastien Hulot, Etienne Puymirat
| Article suivant Article suivant
  • Enhancing capsule in hepatocellular carcinoma: intra-individual comparison between CT and MRI with extracellular contrast agent
  • Roberto Cannella, Maxime Ronot, Riccardo Sartoris, Francois Cauchy, Christian Hobeika, Aurélie Beaufrere, Loïc Trapani, Valérie Paradis, Mohamed Bouattour, Fanny Bonvalet, Valérie Vilgrain, Marco Dioguardi Burgio

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.