S'abonner

False Positive Responses in Standard Automated Perimetry - 12/12/21

Doi : 10.1016/j.ajo.2021.06.026 
Anders Heijl 1, 2, ⁎ , Vincent Michael Patella 3, John G. Flanagan 4, Aiko Iwase 5, Christopher K. Leung 6, Anja Tuulonen 7, Gary C. Lee 8, Thomas Callan 8, Boel Bengtsson 1, 2
1 From Ophthalmology Research Unit, Department of Clinical Sciences Malmö, Lund University (A.H. and B.B.) 
2 Department of Ophthalmology, Skåne University Hospital, Malmö, Sweden (A.H.) 
3 Department of Ophthalmology (V.M.P.), University of Iowa, Iowa City, Iowa, USA 
4 School of Optometry and Vision Science Program (J.G.F.), University of California, Berkeley, Berkeley, USA 
5 Tajimi Iwase Eye Clinic (A.I.), Tajimi, Japan 
6 Department of Ophthalmology and Visual Sciences (C.K.L.), Chinese University of Hong Kong, Hong Kong, China 
7 Tays Eye Centre (A.T.), Tampere University Hospital, Tampere, Finland 
8 Carl Zeiss Meditec, Inc. (G.C.L., T.C.), Dublin, California, USA 

⁎Inquiries to Anders Heijl, Department of Ophthalmology, Skåne University Hospital, Jan Waldenströms Gata 24, SE-20502, Malmö, Sweden.Department of OphthalmologySkåne University HospitalJan Waldenströms Gata 24MalmöSE-20502Sweden

Résumé

Purpose

To analyze the relationship between rates of false positive (FP) responses and standard automated perimetry results.

Design

Prospective multicenter cross-sectional study.

Methods

One hundred twenty-six patients with manifest or suspect glaucoma were tested with Swedish Interactive Thresholding Algorithm (SITA) Standard, SITA Fast, and SITA Faster at each of 2 visits. We calculated intervisit differences in mean deviation (MD), visual field index (VFI), and number of statistically significant test points as a function of FP rates and also as a function of general height (GH).

Results

Increasing FP values were associated with higher MD values for all 3 algorithms, but the effects were small, 0.3 dB to 0.6 dB, for an increase of 10 percentage points of FP rate, and for VFI even smaller (0.6%-1.4%). Only small parts of intervisit differences were explained by FP (r2 values 0.00-0.11). The effects of FP were larger in severe glaucoma, with MD increases of 1.1 dB to 2.0 dB per 10 percentage points of FP, and r2 values ranging from 0.04 to 0.33. The numbers of significantly depressed total deviation points were affected only slightly, and pattern deviation probability maps were generally unaffected. GH was much more strongly related to perimetric outcomes than FP.

Conclusions

Across 3 different standard automated perimetry thresholding algorithms, FP rates showed only weak associations with visual field test results, except in severe glaucoma. Current recommendations regarding acceptable FP ranges may require revision. GH or other analyses may be better suited than FP rates for identifying unreliable results in patients who frequently press the response button without having perceived stimuli.

Le texte complet de cet article est disponible en PDF.

Keywords : False positive responses, Perimetry, Standard Automated Perimetry, Visual Field Testing, Reliability Parameters, Glaucoma


Plan


 Supplemental Material available at AJO.com.


© 2021  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 233

P. 180-188 - janvier 2022 Retour au numéro
Article précédent Article précédent
  • Optical Microangiography and Progressive Retinal Nerve Fiber Layer Loss in Primary Open Angle Glaucoma
  • Harsha L. Rao, Srilakshmi Dasari, Narendra K. Puttaiah, Zia S. Pradhan, Sasan Moghimi, Kaweh Mansouri, Carroll A.B. Webers, Robert N. Weinreb
| Article suivant Article suivant
  • Comment on: Individualized Corneal Cross-linking With Riboflavin and UV-A in Ultrathin Corneas: The Sub400 Protocol
  • Rosa Alvarado-Villacorta, Ned Dávila-Ávila, Everardo Hernández-Quintela

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.