S'abonner

Characterization of Retinal Function Using Microperimetry-Derived Metrics in Both Adults and Children With RPGR-Associated Retinopathy - 02/02/22

Doi : 10.1016/j.ajo.2021.07.018 
Evgenia Anikina a, b, Michalis Georgiou a, b, c, James Tee a, b, Andrew R. Webster a, b, Richard G. Weleber d, Michel Michaelides a, b,
a Moorfields Eye Hospital (E.A., M.G., J.T., A.R.B., M.M.), London, United Kingdom 
b From the University College London Institute of Ophthalmology (E.A., M.G., J.T., A.R.B., M.M.), University College London, London, United Kingdom 
c Department of Ophthalmology, University of Arkansas Medical Sciences, Little Rock, Arkansas, USA. 
d Casey Eye Institute, Oregon Health & Science University (R.G.W.), Portland, Oregon, USA 

Inquiries to Michel Michaelides, UCL Institute of Ophthalmology, 11-43 Bath St, London, EC1V 9EL, United KingdomUCL Institute of Ophthalmology11-43 Bath StLondonEC1V 9ELUnited Kingdom

Résumé

PURPOSE

To investigate microperimetry testing of retinitis pigmentosa GTPase regulator gene (RPGR)-associated retinopathy in a cohort of children and adults.

DESIGN

Prospective observational case series.

METHODS

The coefficient of repeatability and intraclass correlation coefficient (ICC) of mean sensitivity (MS) were calculated for mesopic microperimetry. Best-corrected visual acuity (BCVA), contrast sensitivity (CS), MS, total volume (VTOT), and central 3-degree field volume (V3) from volumetric and topographic analyses were acquired.

RESULTS

The study recruited 76 individuals with RPGR (53 adults, 23 children). The mean follow-up period was 2.8 years. The ICC values for MS, VTOT, and V3 were 0.982 dB (95% CI, 0.969-0.989 dB), 0.970 dB-steradian (sr) (95% CI, −0.02658 to 0.03691 dB-sr), and 0.986 dB-sr (95% CI, 0.978-0.991), respectively. The r values for interocular MS, VTOT, and V3 were 0.97 (P < .01), 0.97 (P < .01), and 0.98 (P < .01), respectively, indicating strong interocular correlation. The interocular correlation of progression for MS, VTOT, and V3 was 0.81 (P < .01), 0.64 (P < .01), and 0.81 (P < .01), respectively. There was no statistically significant difference in the interocular progression rates for MS or VTOT. V3 did show a statistically significant difference. Most patients lost retinal sensitivity rapidly during their second and third decades of life.

CONCLUSIONS

The high degree of reproducibility of results and the good interocular correlation lends this method to accurately monitoring disease progression, as well as supporting validation of the use of MP in assessing the outcomes of gene therapy clinical treatment trials.

Le texte complet de cet article est disponible en PDF.

HIGHLIGHTS

Retinitis pigmentosa GTPase regulator gene (RPGR)-associated retinopathy is a predominantly symmetric test.
Microperimetry has a good test-retest reliability for the disease and can track progression of retinal functional loss.
The high degree of reproducibility of results, good interocular correlation, and accurate tracking of change over time lends this modality well to assessing the outcomes of gene therapy trials.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2021  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 234

P. 81-90 - février 2022 Retour au numéro
Article précédent Article précédent
  • Clinicopathologic Characteristics and Prognostic Factors Impacting Survival in Melanoma of the Eyelid
  • Cammille C. Go, Diana H. Kim, Beatrice C. Go, Brendan McGeehan, César A. Briceño
| Article suivant Article suivant
  • Standard Reliability and Gaze Tracking Metrics in Glaucoma and Glaucoma Suspects
  • Andrew Steven Camp, Christopher P Long, Vincent Michael Patella, James A Proudfoot, Robert N Weinreb

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.