S'abonner

Impact of dose reduction and iterative reconstruction algorithm on the detectability of pulmonary nodules by artificial intelligence - 30/04/22

Doi : 10.1016/j.diii.2021.12.002 
Moritz Schwyzer a, b, c, d, Michael Messerli c, e, Matthias Eberhard a, c, Stephan Skawran a, c, e, Katharina Martini a, c, , Thomas Frauenfelder a, c
a Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, 8091 Zurich, Switzerland 
b Health Sciences and Technology, Institute of Food, Nutrition and Health, ETH Zurich, 8603 Schwerzenbach, Switzerland 
c University of Zurich, 8006 Zurich, Switzerland 
d School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, PA 19104, USA 
e Department of Nuclear Medicine, University Hospital Zurich, 8091 Zurich, Switzerland 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

The performance of pulmonary nodule detection by artificial intelligence software is impacted by dose reduction and reconstruction settings.
Chest CT with lower image noise seem to have greater sensitivity and fewer false positive findings compared to reconstruction settings with high image noise when using fully automatic nodule detection software.
When using fully automatic nodule detection software at reduced radiation dose levels, increasing strength levels of iterative reconstruction might improve sensitivity and reduce false positive findings.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

The purpose of this study was to assess whether the performances of an automated software for lung nodule detection with computed tomography (CT) are affected by radiation dose and the use of iterative reconstruction algorithm.

Materials and methods

A chest phantom (Multipurpose Chest Phantom N1; Kyoto Kagaku Co. Ltd, Kyoto, Japan) with 15 pulmonary nodules was scanned with a total of five CT protocol settings with up to 20-fold dose reduction. All CT examinations were reconstructed with iterative reconstruction algorithms ADMIRE 3 and ADMIRE 5 and were then analyzed for the presence of pulmonary nodules with a fully automated computer aided detection software system (InferReadTM CT Lung, Infervision), which is based on deep neural networks.

Results

The sensitivity of fully automated pulmonary nodule detection for ground-glass nodules at standard dose CT was greater (70.0%; 14/20; 95% CI: 51.6-88.4%) than at 10-fold and 20-fold dose reduction (30.0%; 6/20; 95% CI: 0.0%-62.5%). There were less false positive findings when ADMIRE 5 reconstruction was used (4.0 ± 2.8 [SD]; range: 2–6) instead of ADMIRE 3 reconstruction (25.0 ± 15.6 [SD]; range: 14–36). There was no difference in the sensitivity of detection of solid and subsolid nodules between standard dose (100%; 95% CI: 100–100%) and 10- and 20-fold reduced dose CT (92.5%; 95% CI: 83.8–100.0%). Image noise was significantly greater with ADMIRE 3 (81 ± 2 [SD] [range: 79–84]; 104 ± 3 [SD] [range: 101–107]; 114 ± 5 [SD] [range: 110–119]; 193 ± 10 [SD] [range: 183-203]; 220 ± 16 [SD] [range: 210–238]) compared to ADMIRE 5 (44 ± 2 [SD] [range: 42–46]; 60 ± 2 [SD] [range: 57–61]; 66 ± 1 [SD] [range: 65–67]; 103 ± 4 [SD] [range: 98–106]; 110 ± 1 [SD] [range: 109–111]), respectively in each of the five CT protocols.

Conclusion

This phantom study suggests that dose reduction and iterative reconstruction settings have an impact on detectability of pulmonary nodules by artificial intelligence software and we therefore encourage adaption of dose levels and reconstruction methods prior to widespread implementation of fully automatic nodule detection software for lung cancer screening purposes.

Le texte complet de cet article est disponible en PDF.

Keywords : Artificial intelligence, Dose reduction, Iterative reconstruction algorithm, Lung nodule, Nodule detection

Abbreviations : ADMIRE, CI, CNR, CT, DLP, HU, kV, mAs, mSv, PACS, ROI


Plan


© 2021  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 103 - N° 5

P. 273-280 - mai 2022 Retour au numéro
Article précédent Article précédent
  • Accuracy of a CT density threshold enhancement to identify pancreatic parenchyma necrosis in acute pancreatitis during the first week
  • Jean Pierre Tasu, Raphael Le Guen, Inès Ben Rhouma, Ayoub Guerrab, Nadeem Beydoun, Brice Bergougnoux, Pierre Ingrand, Guillaume Herpe
| Article suivant Article suivant
  • Unexpected discovery of ballistic metallic foreign bodies on postmortem imaging examinations
  • Sylvain Grange, Carolyne Bidat-Callet, Rémi Grange, Fabrice-Guy Barral, Michel Peoc'h, Thema Mokrane, Fabrice Dedouit

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.