S'abonner

External Validation of a Laboratory Prediction Algorithm for the Reduction of Unnecessary Labs in the Critical Care Setting - 24/05/22

Doi : 10.1016/j.amjmed.2021.12.020 
Linda T. Li, MD a, ⁎ , Tongtong Huang, MCS b, Elmer V. Bernstam, MD, MSE, MS b, c, Xiaoqian Jiang, PhD b
a Department of Pediatric Surgery; McGovern Medical School at The University of Texas Health Science Center at Houston 
b School of Biomedical Informatics, The University of Texas Health Science Center at Houston 
c Department of Internal Medicine, McGovern Medical School at The University of Texas Health Science Center at Houston 

⁎Requests for reprints should be addressed to Linda T. Li, MD, Department of Pediatric Surgery, McGovern Medical School at The University of Texas Health Science Center at Houston, 6431 Fannin St., MSB 5.250, Houston, TX 77030.Department of Pediatric SurgeryMcGovern Medical School at The University of Texas Health Science Center at Houston6431 Fannin St., MSB 5.250HoustonTX77030

Abstract

Background

Unnecessary laboratory tests contribute to iatrogenic harm and are a major source of waste in the health care system. We previously developed a machine learning algorithm to help clinicians identify unnecessary laboratory tests, but it has not been externally validated. In this study, we externally validate our machine learning algorithm.

Methods

To externally validate the machine learning algorithm that was originally trained on the Medical Information Mart for Intensive Care (MIMIC) III database, we tested the algorithm in a separate institution. We identified and abstracted data for all patients older than 18 years admitted to the intensive care unit at Memorial Hermann Hospital in Houston, Texas (MHH) from January 1, 2020 to November 13, 2020. Using the transfer learning style, we performed external validation of the machine learning algorithm.

Results

A total of 651 MHH patients were included. The model performed well in predicting abnormality (area under the curve [AUC] 0.98 for MIMIC III and 0.89 for MHH). The model performed similarly in predicting transitions from normal laboratory range to abnormal (AUC 0.71 for MIMIC III and 0.70 for MHH). The performance of the model in predicting the actual laboratory value was also similar in the MIMIC III (accuracy 0.41) and MHH data (0.45).

Conclusions

We externally validated the machine learning model and showed that the model performed similarly, supporting the generalizability to other settings. While this model demonstrated good performance for predicting abnormal labs and transitions, it does not perform well enough for prediction of laboratory values in most clinical applications.

Le texte complet de cet article est disponible en PDF.

Keywords : Critical care patients, External validation, Laboratory prediction, Machine learning, Predictive analytics


Plan


 Funding: This work was supported in part by the National Center for Advancing Translational Sciences (NCATS) under awards U01TR002062, UL1TR000371 and U01TR002393; the National Institute of Aging (NIA) under award (R01AG066749), the Cancer Prevention and Research Institute of Texas (CPRIT), under award RP170668, RR180012 and the Reynolds and Reynolds Professorship in Clinical Informatics.
 Conflicts of Interest: The authors have no competing interests or financial relationships relevant to this article to disclose.
 Authorship: All authors had access to the data and a role in the manuscript writing. LTL: Conceptualization, project administration, roles/writing – original draft. TH: Data curation, formal analysis, validation; writing – review & editing. EVB: Conceptualization, resources, writing – review & editing. XJ: Conceptualization, formal analysis, methodology, supervision, writing – review & editing.


© 2022  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 135 - N° 6

P. 769-774 - juin 2022 Retour au numéro
Article précédent Article précédent
  • Added Prognostic Value of Plaque Burden to Computed Tomography Angiography and Myocardial Perfusion Imaging in Patients with Diabetes
  • Talal Alnabelsi, Ahmed Ibrahim Ahmed, Yushui Han, Mahmoud Al Rifai, Faisal Nabi, Miguel Cainzos-Achirica, Mouaz H. Al-Mallah
| Article suivant Article suivant
  • Relationship of Physical Examination Technique to Associated Clinical Skills: Results from a Direct Observation Assessment
  • Bennett W. Clark, Timothy Niessen, Ariella Apfel, Joyce Luckin, Yi Zhen Joan Lee, Sanjay V. Desai, Brian T. Garibaldi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.