A back table ultraviolet light decreases environmental contamination during operative cases - 25/05/22

Doi : 10.1016/j.ajic.2021.09.020 
Jason M. Jennings, MD, DPT a, b, , Todd M. Miner, MD a, Roseann M. Johnson, BS a, Aviva K. Pollet, BS a, Anna C. Brady, BS a, Douglas A. Dennis, MD a, b, c, d
a Colorado Joint Replacement, Denver CO 
b Department of Biomedical Engineering, University of Denver, Denver, CO 
c Department of Biomedical Engineering, University of Tennessee, Knoxville, TN 
d Department of Orthopaedics, University of Colorado Health School of Medicine, Aurora, CO 

Address correspondence to Jason M. Jennings, MD DPT, Colorado Joint Replacement, 2535 S Downing St Suite 100, Denver CO 80210.Colorado Joint Replacement2535 S Downing St Suite 100DenverCO80210

Highlights

UV-LED has recently been introduced as a potential alternative to traditional UV light.
Germicidal UV-LED may decrease environmental contamination near the operative field.
This technology has the potential to decrease periprosthetic joint infection.

Le texte complet de cet article est disponible en PDF.

Résumé

Background

The purpose of this study is to assess the impact of a germicidal ultraviolet light-emitting diode (LED) on the contamination level of a back table in the operating room (OR) during total joint arthroplasty procedures.

Methods

Eight Tryptic Soy Agar petri plates were placed on a table located near the operative field and exposed to air. One plate was removed on the hour over an 8-hour time span. The back table had either an UV-LED for disinfection or a sham UV-LED. This process was repeated in 12 different ORs (6 with UV light, 6 with sham device). The plates were then incubated for 48 hours at 36°C ± 1°C . Colony forming units (CFU) were recorded 24 and 48 hours after incubation.

Results

There was a statistically significant difference in total CFUs between the intervention vs sham at 24-hours (27 vs 95, P = .0001) and 48-hours (38 vs 122, P < .0001). The multivariate analysis revealed that the 24-hour and 48-hour count, the predictors UV light (P = .002) and hour of plate removal (P = .050) were statistically significantly associated with CFU counts. Together, the predictor variables explained 15.8% and 23.0% of the variance in CFU counts at 24- and 48-hours, respectively.

Conclusions

A back table UV-LED may decrease environmental contamination near the operative field. This has potential to lead to a decrease in joint infection.

Le texte complet de cet article est disponible en PDF.

Key Words : Infection, Colony forming units, Light-emitting diode, Germicidal


Plan


 Conflicts of interest: None to report.


© 2021  Association for Professionals in Infection Control and Epidemiology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 50 - N° 6

P. 686-689 - juin 2022 Retour au numéro
Article précédent Article précédent
  • Prolonged outbreak of clonal, mupirocin-resistant methicillin-resistant Staphylococcus aureus in a neonatal intensive care unit: association with personnel and a possible environmental reservoir, analyzed using whole genome sequencing
  • Lorry G Rubin, Joanna Beachy, Tara Matz, Archana Balamohan, Linda Jendresky, Jill Zembera, Medini K Annavajhala, Anne-Catrin Uhlemann
| Article suivant Article suivant
  • Bacterial urine profile and optimal urine specimen collection timing in asymptomatic chronically catheterized adults with spinal cord injuries and disorders
  • Felipe Camacho-Cordovez, M. Kristi Henzel, Laurie Bauer, Nadim G. El Chakhtoura, Kristen Leili, Federico Perez, Jessica A. Vida-Clough, Brian Klonowski, Patricia Kiefer, Curtis J. Donskey, Maria E. Navas

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.