S'abonner

A systematic review examining the pulmonary effects of electronic vapor delivery systems - 08/09/22

Doi : 10.1016/j.jclinane.2022.110952 
Corinne E. Novelli, DNP, CRNA a, Elizabeth J. Higginbotham, DNP, CRNA a, Karen A. Kapanke, DNP, CRNA b , Kashica J. Webber-Ritchey, PhD, MHA, RN c , Christopher H. Parker, PhD, MS d , Shannon D. Simonovich, PhD, RN c,
a University of Chicago Medical Center, Chicago, IL, United States of America 
b Northshore University HealthSystem School of Nurse Anesthesia, Evanston, IL, United States of America 
c School of Nursing, College of Science and Health, DePaul University, 990 W Fullerton, Chicago, IL, United States of America 
d DePaul University Libraries, 2350 N Kenmore Ave, Chicago, IL 60614, United States of America 

Corresponding author.

Abstract

Study objective

Despite the popularity of vaping and electronic vapor delivery systems (EVDS), the healthcare community remains largely unfamiliar with their potential to induce harm. The purpose of this systematic review is to identify how EVDS use affects the pulmonary system in order to support future anesthetic guidelines for patients who vape.

Design

Systematic Review. An electronic search of databases CINAHL and PubMed was performed in October 2020.

Study eligibility criteria

Studies were included if they were deemed original research published in English, if they were performed exclusively in humans or on human tissue, if they examined the effects of EVDS on pulmonary function or tissue, and/or if they produced quantitative data. Studies were excluded if they utilized animal samples, studied subjects under the age of 18, presented expert opinions or reviews, offered qualitative data, reported case studies, or only evaluated EVDS' efficacy as a smoking cessation tool.

Main results

This review identified six EVDS-induced pulmonary implications warranting anesthetic consideration: alterations in pulmonary function tests, disrupted ventilation, impaired mucociliary clearance, tissue destruction, a disrupted immune response, and oxidative stress with DNA fragmentation.

Conclusion

A total of 38 studies described the effects of EVDS on pulmonary function, airway epithelial tissue, and inflammatory mechanisms that may lead to chronic pulmonary disease. Anesthesia providers are encouraged to assess patients for EVDS use during the preoperative period and use the information generated by this systematic review to drive subsequent care.

Le texte complet de cet article est disponible en PDF.

Highlights

Electronic Vapor Delivery systems have significant negative impacts on pulmonary function.
Electronic Vapor Delivery systems disrupt pulmonary function and increase airway resistance.
Electronic Vapor Delivery systems create alterations in ventilation and impair mucociliary clearance.
Anethesia providers should assess patients for Electronic Vapor Delivery system usage during perioperative encounters.

Le texte complet de cet article est disponible en PDF.

Keywords : Vaping, Anesthesia, Electronic cigarette, Electronic vapor delivery system, Pulmonary function


Plan


© 2022  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 82

Article 110952- novembre 2022 Retour au numéro
Article précédent Article précédent
  • Does residency program social media activity correlate with prospective applicant interest?
  • Max M. Feinstein, Ira Schlosberg, Da Wi Shin, Cynthia R. Mercedes, Matthew Sison, Daniel Katz, Marc Sherwin
| Article suivant Article suivant
  • Corrigendum to “Preoperative sedation in children with congenital heart disease: 50% and 95% effective doses, hemodynamic effects, and safety of intranasal dexmedetomidine”. [Journal of Clinical Anesthesia, Volume 81, (2022)/ Article 110908]
  • Lin Qiu, Longyin Cao, Zhibin Lang, Xue Li, Hongqi Lin, Taibing Fan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.