Résumé

Reducing radiation exposure during cardiovascular catheterization is of paramount importance to ensure patient and staff safety. Our study aimed to assess the transferability of acquired skills from virtual reality to the real world, including radioprotection measures during mentored simulation training (ST) in coronary angiography. A total of 10 cardiology residents were evaluated during real-life cases in the catheterization laboratory before (group A) and after mentored ST. The educational effect of mentored simulator training on real-life case performance was evaluated at 2 different time points: within the first week (group B) and after 12 weeks (group C). Compared with group A, the total dose area product (DAP) (µGy•m2) and total air kerma (mGy) were lower after ST: group A: 2,633 (1,723 to 3,617) versus group B: 1,618 (1,032 to 2,562), p <0.05 and 214 (136 to 297) versus 135 (84 to 222), p <0.05, respectively. Concerning operator radiation exposure (µSv), left finger dose: 1,090 (820 to 1,460) versus 635 (300 to 900), p = 0.028; left leg dose 80 (0 to 110) versus 0 (0 to 0), p = 0.027; left eye lens dose: 39 (24 to 69) versus 11 (8 to 20), p <0.0001; and chest dose outside the lead apron: 50 (34 to 88) versus 29 (21 to 50), p <0.003 were significantly lower in the group B than group A. A total of 12 weeks after ST, the total DAP and total air kerma remained stable along with operator exposure except left eye lens dose (µSv): group B: 11 (8 to 20) versus group C: 16 (12 to 27), p = 0.02. In addition, left eye lens dose, left wrist dose, and chest dose outside the lead apron were significantly correlated with total DAP (rs = 0.635, rs = 0.729, and rs = 0, 629, respectively) and total air kerma (rs = 0.488, rs = 0.514, and rs = 0.548, respectively) at 12 weeks. In conclusion, ST for coronary angiography may improve radioprotection learning and should be incorporated into training curricula.

Le texte complet de cet article est disponible en PDF.

Plan


 Funding: None.


© 2022  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 181

P. 25-31 - octobre 2022 Retour au numéro
Article précédent Article précédent
  • Adverse Impact of Peri-Procedural Stroke in Patients Who Underwent Percutaneous Coronary Intervention
  • Noah Z. Wexler, Sara Vogrin, Angela L. Brennan, Samer Noaman, Omar Al-Mukhtar, Kawa Haji, Jason E. Bloom, Diem T. Dinh, Wayne C. Zheng, James A. Shaw, Stephen J. Duffy, Jeffrey Lefkovits, Christopher M. Reid, Dion Stub, David M. Kaye, Nicholas Cox, William Chan
| Article suivant Article suivant
  • Usefulness of Self-Reported Physical Activity and Clinical Outcomes in Older Patients With Atrial Fibrillation
  • Qiying Dai, Jordy Mehawej, Jane S. Saczynski, Khanh-Van Tran, Hawa O. Abu, Darleen Lessard, Andreas Fillippaios, Tenes Paul, Essa Hariri, Weijia Wang, Mayra Tisminetzky, Apurv Soni, Sakeina Howard-Wilson, Molly E. Waring, Robert J. Goldberg, David D. McManus

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.