S'abonner

Vigorous Physical Activity as a Risk Factor for Central Serous Chorioretinopathy - 25/11/22

Doi : 10.1016/j.ajo.2022.08.002 
Felice Cardillo Piccolino 1, , Daniela Fruttini 2, Chiara Eandi 3, 4, Massimo Nicolò 5, Cesare Mariotti 6, Silvia Tito 1, Marco Lupidi 1, 5
1 Fondazione per la Macula Onlus (F.C.P., S.T., M.L.), Dipartimento di Neuroscienze, Riabilitazione, Oftalmologia, Genetica e Scienze Materno-Infantili (DINOGMI), University Eye Clinic, Genova, Italy 
2 Department of Medicine and Surgery (D.F.), University of Perugia, S. Maria della Misericordia Hospital, Perugia, Italy 
3 Department of Ophthalmology (C.E.), University of Lausanne, Jules-Gonin Eye Hospital, Fondation Asile des Aveugles, Lausanne, Switzerland Centre de l'Odéon, Paris, France 
4 Department of Surgical Sciences (C.E.), Eye Clinic, University of Torino, Torino, Italy 
5 Clinica Oculistica (M.N.), DiNOGMI, Università di Genova - IRCCS Ospedale Policlinico San Martino, Genova, Italy 
6 Eye Clinic (C.M., M.L.), Department of Experimental and Clinical Medicine, Polytechnic University of Marche, Ancona, Italy 

Inquiries to Felice Cardillo Piccolino, Fondazione per la Macula Onlus, Genova, Italy.Fondazione per la Macula OnlusGenovaItaly

Résumé

PURPOSE

To evaluate whether frequent vigorous physical activity (PA) is significantly associated with active central serous chorioretinopathy (CSCR) and may represent a risk factor for CSCR.

DESIGN

Case-control study.

METHODS

This was a multicenter study. The patient population comprised consecutive patients with active CSCR and a comparable control group of healthy participants. Both groups were interrogated about their PA using a shortened version of the International Physical Activity Questionnaire. The Ainsworth Compendium of Physical Activities was taken as a reference for the activities requiring vigorous effort and to quantify the energy expended, expressed in metabolic equivalent of task (MET). As a main outcome measure, a moderate/high practice of vigorous PA was opposed to an absent/low practice of vigorous PA in the 2 groups.

RESULTS

A total of 105 patients with CSCR and 105 healthy controls were included in the study. Moderate/high vigorous PA was observed in 63.5% of the patients with CSCR and in 26% of the controls (P = .0001). The MET values of vigorous PA were 2173.2 ± 2081.5 in the CSCR group and 1216.3 ± 524 in the control group (P = .029). The potential risk of disease associated with moderate/high vigorous PA was 5.58 (odds ratio; 95% confidence interval 3.01-10.69, P = .0001).

CONCLUSIONS

This study demonstrates a significant association of vigorous PA with CSCR, indicating an increased probability of disease by 5.58 times. Frequent and intense PA, with the hypertensive episodes that it entails, can break the precarious hemodynamic balance in the choroid of individuals predisposed to CSCR, thereby favoring choroidal vascular decompensation and active disease.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2022  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 244

P. 30-37 - décembre 2022 Retour au numéro
Article précédent Article précédent
  • Impact of the Time to Surgery on Visual Outcomes for Rhegmatogenous Retinal Detachment Repair: A Meta-Analysis
  • Amirthan Sothivannan, Arshia Eshtiaghi, Arjan S. Dhoot, Marko M. Popovic, Sunir J. Garg, Peter J. Kertes, Rajeev H. Muni
| Article suivant Article suivant
  • Pentosan Polysulfate Sodium-Associated Maculopathy: Early Detection Using OCT Angiography and Choriocapillaris Flow Deficit Analysis
  • Meira Fogel Levin, Ahmad Santina, Giulia Corradetti, Adrian Au, Anthony Lu, Neda Abraham, Swathi Somisetty, Veronica Romero Morales, Alice Wong, SriniVas Sadda, David Sarraf

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.