Aim

The Occlutech duct occluder (ODO) with a novel design has been available for closure of patent ductus arteriosus (PDA) since 2011. Available data on initial experience with the ODO have shown that operators continue to choose device sizes based on their experience with conventional duct occluders (CDO). This study postulated that occlusion of the pulmonary arterial (PA) end of the ductus should achieve satisfactory PDA closure without additional complications. Accordingly, the size of the ODO was chosen such that the larger PA diameter in the new design exceeded the PA end of the ductus by 2–3 mm and 2–4 mm for normotensive and hypertensive ducts, respectively. It sought to examine the feasibility and safety of such an approach, and compared ODO and CDO devices with respect to device sizes deployed, to ascertain if the newer design had any advantages.

Methods

This prospective study enrolled 105 infants, children and a few adults with various duct morphologies and PA pressures for ductal closure using the ODO from 2018–2020. The control group consisted of 105 ducts closed with CDO. A comparison of the two groups with respect to duct diameter and implanted device sizes was performed using appropriate statistical software.

Results

The study found that 40% of the ducts had moderate-to-severe pulmonary hypertension. Most ducts measured between 3–4 mm in both groups. The mean weight of the subjects in both groups was 12 kg. Although there was no change in the way that duct occluders were chosen in both groups (2–3 mm over the pulmonary artery diameter), ODO could be significantly downsized in most ducts measuring between 2.5–6.4 mm in diameter (p<0.05).

Conclusions

This study found successful closure of relatively larger PDA in infants and children using smaller ODO compared with CDO, without embolisation or aortic narrowing. It also demonstrated that a different device size selection technique may be safely employed with the ODO.

Le texte complet de cet article est disponible en PDF.

Keywords : Patent ductus arteriosus, Occlutech, Duct occluder, Conventional design, Size selection


Plan


© 2022  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 31 - N° 12

P. 1677-1684 - décembre 2022 Retour au numéro
Article précédent Article précédent
  • Efficacy of Off-Pump Coronary Artery Bypass Grafting With Concomitant Transcatheter Aortic Valve Replacement
  • Yusuke Shimahara, Satsuki Fukushima, Hideaki Kanzaki, Yasuhide Asaumi, Makoto Amaki, Naonori Kawamoto, Satoshi Kainuma, Naoki Tadokoro, Takashi Kakuta, Kensuke Takagi, Michikazu Nakai, Junjiro Kobayashi, Tomoyuki Fujita
| Article suivant Article suivant
  • Outcomes of Cardiac Transplantation in Western Australia – A Contemporary Single Centre Experience
  • Umar Ali, Lauren Giudicatti, Felicity Lee, Clare Fazackerley, Karim Slimani, Chris Merry, Amit Shah, Robert Larbalestier

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.