S'abonner

BAlloon expandable vs. SElf expanding transcatheter vaLve for degenerated bioprosthesIs: design and rationale of the BASELINE trial - 12/01/23

Doi : 10.1016/j.ahj.2022.11.013 
Rutger-Jan Nuis, MD PhD a, Eric van Belle, MD PhD b, Rui Teles, MD PhD c, Daniel Blackman, MD PhD d, Verena Veulemans, MD PhD e, Ignacio Amat Santos, MD PhD f, Thomas Pilgrim, MD PhD g, Giuseppe Tarantini, MD PhD h, Francesco Saia, MD PhD i, Ioannis Iakovou, MD PhD j, Julia Mascherbauer, MD PhD k, Flavien Vincent, MD PhD b, Marcel Geleijnse, MD PhD a, Janarthanan Sathananthan, MD PhD l, David Wood, MD PhD l, Raj Makkar, MD PhD m, Nicolas M. Van Mieghem, MD PhD a, ⁎
On behalf of the

BASELINE Investigators

a Department of Cardiology, Erasmus University Medical Center, Rotterdam, Netherlands 
b Department of Cardiology, Institut Cœur Poumon, Lille, France 
c Hospital de Santa Cruz, CHLO; Nova Medical School, Lisbon, Portugal 
d Department of Cardiology, Leeds Teaching Hospitals NHS Trust, Leeds, United Kindom 
e Division of Cardiology, Heinrich Heine University Medical Center Dusseldorf, Dusseldorf, Germany 
f Departamento de Cardiología, Hospital Clínico Universitario, Valladolid, Spain 
g Department of Cardiology, Bern University Hospital, University of Bern, Bern, Switzerland 
h Department of Cardiac, Thoracic, Vascular Science and Public Health, University of Padova, Padua, Italy 
i U.O. Cardiologia, Dipartimento Cardio-Toraco-Vascolare, Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy 
j Department of Cardiology, Onassis Cardiac Surgery Center, Athens, Greece 
k Department of Cardiology, University Hospital St. Polten, Sankt Pölten, Austria 
l Centre for Cardiovascular and Heart Valve Innovation, St. Paul's and Vancouver General Hospital, Vancouver, Canada 
m Department of Cardiology, Cedars-Sinai Medical Center, Los Angeles, CA 

⁎Reprint requests: Nicolas M. Van Mieghem, MD, PhD, Department of Interventional Cardiology, Erasmus University Medical Center, Room Nt-645, Dr. Molewaterplein 40, Rotterdam, The Netherlands 3015 GDDepartment of Interventional CardiologyErasmus University Medical CenterRoom Nt-645, Dr. Molewaterplein 40Rotterdam3015 GDThe Netherlands

Résumé

Background

Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis.

Methods

The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies.

Conclusions

The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).

Le texte complet de cet article est disponible en PDF.

Plan


© 2022  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 256

P. 139-147 - février 2023 Retour au numéro
Article précédent Article précédent
  • Rationale and design of the TUXEDO-2 India study: Ultra-Thin strUt Supraflex Cruz versus XiencE in a Diabetic pOpulation with multi-vessel disease–2
  • Upendra Kaul, Priyadarshini Arambam, Santosh Kumar Sinha, Rajpal Abhaichand, Ashok Kumar Parida, Darshan Banker, Rohit Mody, Aziz Khan, Rajesh Sharma, Nagaraja Moorthy, Sharad Chandra, Sarat Chandra Koduganti, Rajeev Garg, Polavarapu Raghava Sarma, Deepesh Kumar Agrawal, K M K Reddy, Sripal Bangalore
| Article suivant Article suivant
  • Prognosis of acute coronary syndrome stratified by cancer type and status - a nationwide cohort study
  • Nina Nouhravesh, Jarl E. Strange, Jacob Tønnesen, Anders Holt, Camilla F. Andersen, Mads H. Jensen, Ali Al-Alak, Maria D'Souza, Dorte Nielsen, Kristian Kragholm, Emil L. Fosbøl, Morten Schou, Morten K. Lamberts

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.